A prospective study of microscope-integrated intraoperative fluorescein videoangiography during arteriovenous malformation surgery

intraoperative fluorescein videoangiography during arteriovenous malformation surgery

Neurosurg Focus 36 (2):E15, 2014

The authors report on the use of a recently developed microscope-integrated fluorescent module using low-dose intravenous fluorescein for videoangiography during arteriovenous malformation (AVM) surgery.

Methods. The authors analyzed the application of a low-dose intraoperative fluorescein in 4 consecutive patients undergoing AVM surgery. The ability to distinguish the associated vessels of the AVM from normal vessels and to assess the degree of AVM obliteration based on videoangiography of venous drainage was specifically analyzed.

Results. All 4 patients underwent fluorescein angiography without complication. In each case, videoangiography confirmed recognition of feeding arteries and draining veins through the operating oculars under the fluorescent mode. In one case involving a large frontal AVM, videoangiography demonstrated mainly cortical veins on the surface of the AVM and alerted the senior author to first tackle the feeding arteries in the interhemispheric space. While evaluating the flow within the different draining veins after most of the AVM was disconnected, videoangiography also prioritized the order for disconnection of large draining veins to allow mobilization the AVM and exposure of the remaining deep arterial feeders. In the other 3 cases, videoangiography allowed easy recognition of the angioarchitecture of the AVMs, estimated its cortical boundaries, and most importantly, assessed the flow within the draining veins before their disconnection.

Conclusions. The authors found fluorescein videoangiography to be a useful adjunct in resection of AVMs. This technology offers the unique ability to visualize fluorescent vessels and nonfluorescent tissues in near-natural colors simultaneously and permits microsurgical manipulation of relevant structures under the fluorescent mode. Largerscale studies are needed to establish its efficacy and wider applicability.

Essentials in intraoperative indocyanine green videoangiography assessment for intracranial aneurysm surgery

ICG aneurysm

Neurosurg Focus 36 (2):E7, 2014

Indocyanine green (ICG) videoangiography (VA) in cerebral aneurysm surgery allows confirmation of blood flow in parent, branching, and perforating vessels as well as assessment of remnant aneurysm parts after clip application. A retrospective analysis and review of the literature were conducted to determine the current essential advantages of ICG-VA in aneurysm surgery.

Methods. The authors retrospectively evaluated all aneurysm cases treated with the aid of intraoperative ICG-VA at a single institution between 2007 and 2013. They also analyzed the literature published since the initial description of ICG-VA in 2003.

Results. Two hundred forty-six procedures were performed in 232 patients harboring 295 aneurysms. The pa- tients, whose mean age was 54 years, consisted of 159 women and 73 men. One hundred twenty-four surgeries were performed after subarachnoid hemorrhage, and 122 were performed for incidental aneurysms. Single aneurysms were clipped in 185 patients, and multiple aneurysms were clipped in 47 (mean aneurysm diameter 6.9 mm, range 2–40 mm). No complications associated with ICG-VA occurred. Intraoperative microvascular Doppler ultrasonography was performed before ICG-VA in all patients, and postoperative digital subtraction angiography (DSA) studies were available in 121 patients (52.2%) for retrospective comparative analysis. In 22 (9%) of 246 procedures, the clip posi- tion was modified intraoperatively as a consequence of ICG-VA. Stenosis of the parent vessels (16 procedures) or occlusion of the perforators (6 procedures), not detected by micro-Doppler ultrasonography, were the most common problems demonstrated on ICG-VA. In another 11 procedures (4.5%), residual perfusion of the aneurysm was ob- served and one or more additional clips were applied. Vessel stenosis or a compromised perforating artery occurred independent of aneurysm location and was about equally common in middle cerebral artery and anterior communi- cating artery aneurysms. In 2 procedures (0.8%), aneurysm puncture revealed residual blood flow within the lesion, which had not been detected by the ICG-VA. In the postoperative DSA studies, unexpected small (< 2 mm) aneurysm neck remnants, which had not been detected on intraoperative ICG-VA, were found in 11 (9.1%) of 121 patients. However, these remnants remained without consequence except in 1 patient with a 6-mm residual aneurysm dome, which was subsequently embolized with coils.

Conclusions. In a large cohort of consecutive patients, ICG-VA proved to be a helpful intraoperative tool and led to a significant intraoperative clip modification rate of 15%. However, small, < 2-mm-wide neck remnants and a 6-mm residual aneurysm were missed by intraoperative ICG-VA in up to 10% of patients. Results in this study confirm that DSA is indispensable for postoperative quality assessment in complex aneurysm surgery.

Near-infrared imaging of brain tumors using the Tumor Paint BLZ-100 to achieve near-complete resection of brain tumors

Near-infrared imaging of brain tumors using the Tumor Paint BLZ-100 to achieve near-complete resection of brain tumors

Neurosurg Focus 36 (2):E1, 2014

The intraoperative clear delineation between brain tumor and normal tissue in real time is required to ensure near-complete resection without damaging the nearby eloquent brain. Tumor Paint BLZ-100, a tumor ligand chlorotoxin (CTX) conjugated to indocyanine green (ICG), has shown potential to be a targeted contrast agent. There are many infrared imaging systems in use, but they are not optimized to the low concentration and amount of ICG. The authors present a novel proof-of-concept near-infrared (NIR) imaging system using a standard charge-coupled device (CCD) camera for visualizing low levels of ICG attached to the tumors. This system is small, inexpensive, and sensitive. The imaging system uses a narrow-band laser at 785 nm and a notch filter in front of the sensor at the band. The camera is a 2-CCD camera, which uses identical CCDs for both visible and NIR light.

Methods. The NIR system is tested with serial dilution of BLZ-100 from 1 μM to 50 pM in 5% Intralipid solution while the excitation energy is varied from 5 to 40 mW/cm2. The analog gain of the CCD was changed from 0, 6, and 12 dB to determine the signal-to-noise ratio. In addition to the Intralipid solution, BLZ-100 was injected 48 hours before euthanizing the mice that were implanted with the human glioma cell line. The brain was removed and imaged using the NIR imaging system.

Results. The authors’ results show that the NIR imaging system using a standard CCD is able to visualize the ICG down to 50 nM of concentration with a high signal-to-noise ratio. The preliminary experiment on human glioma implanted in mouse brains demonstrated that BLZ-100 has a high affinity for glioma compared with normal brain tissue. Additionally, the results show that NIR excitation is able to penetrate deeply and has a potential to visualize metastatic lesions that are separate from the main tumor.

Conclusions. The authors have seen that BLZ-100 has a very high affinity toward human gliomas. They also describe a small, cost-effective, and sensitive NIR system for visualizing brain tumors tagged using BLZ-100. The authors hope that the use of BLZ-100 along with NIR imaging will be useful to delineate the brain tumors in real time and assist surgeons in near-complete tumor removal to increase survival and reduce neurological deficits.

5-ALA complete resections go beyond MR contrast enhancement

5-ALA complete resections go beyond MR contrast

Acta Neurochir (2014) 156:305–312

The technique of 5-aminolevulinic acid (5-ALA) tumor fluorescence is increasingly used to improve visualization of tumor tissue and thereby to increase the rate of patients with gross total resections. In this study, we measured the resection volumes in patients who underwent 5-ALA-guided surgery for non-eloquent glioblastoma and compared them with the preoperative tumor volume.

Methods We selected 13 patients who had received a complete resection according to intraoperative 5-ALA induced fluorescence and CRET according to post-operative T1 contrast-enhanced MRI. The volumes of pre-operative contrast enhancing tissue, post-operative resection cavity and resected tissue were determined through shift-corrected volumetric analysis.

Results The mean resection cavity (29 cm3) was marginally smaller than the pre-operative contrast-enhancing tumor (39 cm3, p =0.32). However, the mean overall resection volume (84 cm3) was significantly larger than the pre-operative contrast-enhancing tumor (39 cm3, p=0.0087). This yields a mean volume of resected 5-ALA positive, but radiological non-enhancing tissue of 45 cm3. The mean calculated rim of resected tissue surpassed pre-operative tumor diameter by 6 mm(range 0–10 mm).

Conclusions Results of the current study imply that (i) the resection cavity underestimates the volume of resected tissue and (ii) 5-ALA complete resections go significantly beyond the volume of pre-operative contrast-enhancing tumor bulk on MRI, indicating that 5-ALA also stains MRI non-enhancing tumor tissue. Use of 5-ALA may thus enable extension of coalescent tumor resection beyond radiologically evident tumor. The impact of this more extended resection method on time to progression and overall survival has not been determined, and potentially puts adjacent and functionally intact tissue at risk.

Intraoperative MRI for transsphenoidal pituitary surgery

Intraoperative MRI for transsphenoidal pituitary surgery

J Neurosurg 120:346–356, 2014

Intraoperative MRI (iMRI) provides updated information for neuronavigational purposes and assessments on the status of resection during transsphenoidal surgery (TSS). The high-field technique additionally provides information about vascular structures at risk and precise information about extrasellar residual tumor, making it readily available during the procedure. The imaging, however, extends the duration of surgery. To evaluate the benefit of this technique, the authors conducted a retrospective study to compare postoperative outcome and residual tumor in patients who underwent conventional microsurgical TSS with and without iMRI.

Methods. A total of 143 patients were assessed. A cohort of 67 patients who had undergone surgery before introduction of iMRI was compared with 76 patients who had undergone surgery since iMRI became routine in TSS at the authors’ institution. Residual tumor, complications, hormone dependency, biochemical remission rates, and improvement of vision were assessed at 6-month follow-up. A volumetric evaluation of residual tumor was performed in cases of parasellar tumor extension.

Results. The majority of patients in both groups suffered from nonfunctioning pituitary adenomas. At the 6-month follow-up assessment, vision improved in 31% of patients who underwent iMRI-assisted surgery versus 23% in the conventional group. One instance of postoperative intrasellar bleeding was found in the conventional group. No major complications were found in the iMRI group. Minor complications were seen in 9% of patients in the iMRI group and in 5% of those in the conventional group. No differences between groups were found for hormone dependency and biochemical remission rates. Time of surgery was significantly lower in the conventional treatment group. Overall a residual tumor was found after surgery in 35% of the iMRI group, and 41% of the conventional surgery group harbored a residual tumor. Total resection was achieved as intended significantly more often in the iMRI group (91%) than in the conventional group (73%) (p < 0.034). Patients with a planned subtotal resection showed higher mean volumes of residual tumor in the conventional group. There was a significantly lower incidence of intrasellar tumor remnants in the iMRI group than in the conventional group. Progression-free survival after 30 months was higher according to Kaplan-Meier analysis with the use of iMRI, but a statistically significant difference could not be shown.

Conclusions. The use of high-field iMRI leads to a significantly higher rate of complete resection. In parasellar tumors a lower residual volume and a significantly lower rate of intrasellar tumor remnants were shown with the technique. So far, long-term follow-up is limited for iMRI. However, after 2 years Kaplan-Meier analyses show a distinctly higher progression-free survival in the iMRI group. No significant benefit of iMRI was found for biochemical remission rates and improvement of vision. Even though the surgical time was longer with the adjunct use of iMRI, it did not increase the complication rate significantly. The authors therefore recommend routine use of high-field iMRI for pituitary surgery, if this technique is available at the particular center.

Real-Time Atlas-Based Stereotactic Neuronavigation

Real-Time Atlas-Based Stereotactic Neuronavigation

Neurosurgery 74:128–134, 2014

Surgery for tumors in eloquent brain faces immense challenges when attempting to maximize resection and avoid neurological deficits.

OBJECTIVE: In order to give the surgeon real-time atlas-based anatomic information linked to the patient’s anatomy, we developed a software-based interface between deformable anatomic templates (DATs) and an intraoperative navigation system.

METHODS: Magnetic resonance imaging (MRI), diffusion tensor imaging, and/or functional MRI were performed on 3 patients preoperatively for the purposes of tumor resection by the use of neuronavigation. The DAT was registered to the patients’ navigation coordinate system and utilized coordinates from the navigation system during surgery. This provided the surgeon with a list of proximal anatomic and functional structures and a real-time image of the atlas at that location fused to the patient’s MRI. The clinical feasibility of this approach was evaluated during the resection of 3 eloquent tumors (right postcentral gyrus, left inferior frontal gyrus, and left occipital cuneus gyrus).

RESULTS: Tumor resection was performed successfully in all 3 patients. With the use of the coordinates from the navigation system, anatomic and functional structures and their distances were visualized interactively during tumor resection by using the DAT.

CONCLUSION: This is a proof of concept that an interactive atlas-based navigation can provide detailed anatomic and functional information that supplements MRI, diffusion tensor imaging, and functional MRI. The atlas-based navigation generated distances to important anatomic structures from the navigation probe tip. It can be used to guide direct electrical stimulation and highlight areas to avoid during tumor resection.

Is Intraoperative Diffusion Tensor Imaging at 3.0T Comparable to Subcortical Corticospinal Tract Mapping?

Intraop. DTI

Neurosurgery 73:797–807, 2013

Primary brain tumors in motor eloquent areas are associated with high-risk surgical procedures because of potentially permanent and often disabling motor deficits. Intraoperative primary motor cortex mapping and corticospinal tract (CST) monitoring are well-developed and reliable techniques. Imaging of the CST by diffusion tensor tractography (DTT) is also feasible.

OBJECTIVE: To evaluate the practical value of 3.0T intraoperative MRI (iMRI) with intraoperative DTT (iDTT) in surgery close to the CST, and to compare high-field iDTT with intraoperative neurophysiological CST mapping during glioma and metastasis resection in a routine setting.

METHODS: Twenty-five patients (13 males, 12 females, median 47 years) were enrolled prospectively from June 2010 to June 2012. Patients were included if they had a solitary supratentorial intracerebral lesion compressing or infiltrating the CST according to preoperative MRI. Subcortical CST mapping was performed by monopolar (cathodal) stimulation (500 Hz, 400 ms, 5 pulses). CST DTT was made both at preoperative and intraoperative 3.0T MRI. Subcortical motor-evoked potential threshold current and probe-CST distance were recorded at 155 points before and at 103 points after iMRI. Current-distance correlations were performed both for pre-iMRI and for post-iMRI data.

RESULTS: The correlation coefficient pre-iMRI was R = 0.470 (P , .001); post-iMRI, the correlation coefficient was R = 0.338 (P , .001). MRI radical resection was achieved in 17 patients (68%), subtotal in 5 (24%), and partial in 3 (12%). Postoperative paresis developed in 8 patients (32%); the paresis was permanent in 1 case (4%).

CONCLUSION: The linear current-distance correlation was found both in pre-iMRI and in post-iMRI data. Intraoperative image distortion appeared in 36%. Neurophysiological subcortical mapping remains superior to DTT. Combining these 2 methods in selected cases can help increase the safety of tumor resection close to the CST.

KEY WORDS:

Intraoperative Magnetic Resonance Ventriculography During Endoscopic Third Ventriculostomy

Usefulness of Intraoperative Magnetic Resonance Ventriculography During Endoscopic Third Ventriculostomy

Neurosurgery 73:730–738, 2013

Endoscopic third ventriculostomy (ETV) is the preferred method for the treatment of noncommunicating hydrocephalus. The different success rates of ETV indicate the difficulties in predicting the success of this procedure.

OBJECTIVE: To show the usefulness of intraoperative ventriculography performed by the low-field 0.15-T magnetic resonance imager Polestar N20 during ETV.

METHODS: The study was conducted in 11 patients with noncommunicating hydrocephalus caused by tumors or cysts of the third ventricle (n = 5), nontumoral stenosis of the sylvian aqueduct (n = 3), and fourth ventricle outlet obstruction (n = 3). Intraoperative magnetic resonance (iMR) ventriculography was performed before and after the ETV.

RESULTS: In each case, iMR-ventriculography was a safe procedure and determined the exact site of obstruction of cerebrospinal fluid flow. In all cases, iMR-ventriculography performed after ETV showed with the greatest accuracy the patency of the performed fenestrations, demonstrating in 9 patients good flow of the contrast from the third ventricle to the basal cisterns, restricted flow in 1 patient, and no flow in 1 patient. The results of ventriculography were consistent with the postoperative neurological status of operated-on patients. In 3 patients, the opinion of the surgeons about the patency of endoscopic fenestration, based on intraoperative observation of the third ventricle floor, was inconsistent with the results from iMR-ventriculography.

CONCLUSION: Low-field iMR-ventriculography is a safe procedure that can be successfully applied during ETV to determine the site of obstruction in hydrocephalus and the patency of performed ventricle fenestration.

Intraoperative optical imaging for functional mapping

Intraoperative optical imaging for functional mapping

J Neurosurg 119:853–863, 2013

Intraoperative optical imaging (IOI) is an experimental technique used for visualizing functional brain areas after surgical exposure of the cerebral cortex. This technique identifies areas of local changes in blood volume and oxygenation caused by stimulation of specific brain functions. The authors describe a new IOI method, including innovative data analysis, that can facilitate intraoperative functional imaging on a routine basis. To evaluate the reliability and validity of this approach, they used the new IOI method to demonstrate visualization of the median nerve area of the somatosensory cortex.

Methods. In 41 patients with tumor lesions adjacent to the postcentral gyrus, lesions were surgically removed by using IOI during stimulation of the contralateral median nerve. Optical properties of the cortical tissue were measured with a sensitive camera system connected to a surgical microscope. Imaging was performed by using 9 cycles of alternating prolonged stimulation and rest periods of 30 seconds. Intraoperative optical imaging was based on blood volume changes detected by using a filter at an isosbestic wavelength (delta = 568 nm). A spectral analysis algorithm was used to improve computation of the activity maps. Movement artifacts were compensated for by an elastic registration algorithm. For validation, intraoperative conduction of the phase reversal over the central sulcus and postoperative evaluation of the craniotomy site were used.

Results. The new method and analysis enabled significant differentiation (p < 0.005) between functional and nonfunctional tissue. The identification and visualization of functionally intact somatosensory cortex was highly reliable; sensitivity was 94.4% and specificity was almost 100%. The surgeon was provided with a 2D high-resolution activity map within 12 minutes. No method-related side effects occurred in any of the 41 patients.

Conclusions. The authors’ new approach makes IOI a contact-free and label-free optical technique that can be used safely in a routine clinical setup. Intraoperative optical imaging can be used as an alternative to other methods for the identification of sensory cortex areas and offers the added benefit of a high-resolution map of functional activity. It has great potential for visualizing and monitoring additional specific functional brain areas such as the visual, motor, and speech cortex. A prospective national multicenter clinical trial is currently being planned.

Neuronavigation in minimally invasive spine surgery

Neuronavigation in minimally invasive spine surgery

Neurosurg Focus 35 (2):E12, 2013

Parallel advancements in image guidance technology and minimal access techniques continue to push the frontiers of minimally invasive spine surgery (MISS). While traditional intraoperative imaging remains widely used, newer platforms, such as 3D-fluoroscopy, cone-beam CT, and intraoperative CT/MRI, have enabled safer, more accurate instrumentation placement with less radiation exposure to the surgeon. The goal of this work is to provide a review of the current uses of advanced image guidance in MISS.

Methods. The authors searched PubMed for relevant articles concerning MISS, with particular attention to the use of image-guidance platforms. Pertinent studies published in English were further compiled and characterized into relevant analyses of MISS of the cervical, thoracic, and lumbosacral regions.

Results. Fifty-two studies were included for review. These describe the use of the iso-C system for 3D navigation during C1–2 transarticular screw placement, the use of endoscopic techniques in the cervical spine, and the role of navigation guidance at the occipital-cervical junction. The authors discuss the evolving literature concerning neuronavigation during pedicle screw placement in the thoracic and lumbar spine in the setting of infection, trauma, and deformity surgery and review the use of image guidance in transsacral approaches.

Conclusions. Refinements in image-guidance technologies and minimal access techniques have converged on spinal pathology, affording patients the ability to undergo safe, accurate operations without the associated morbidities of conventional approaches. While percutaneous transpedicular screw placement is among the most common procedures to benefit from navigation, other areas of spine surgery can benefit from advances in neuronavigation and further growth in the field of image-guided MISS is anticipated.

Modern intraoperative imaging modalities for the vascular neurosurgeon treating intracerebral hemorrhage

modern OR

Neurosurg Focus 34 (5):E2, 2013

This paper reviews the current intraoperative imaging tools that are available to assist neurosurgeons in the treatment of intracerebral hemorrhage (ICH). This review shares the authors’ experience with each modality and discusses the advantages, potential limitations, and disadvantages of each.

Surgery for ICH is directed at blood clot removal, reduction of intracranial pressure, and minimization of secondary damage associated with hematoma breakdown products. For effective occlusion and safe obliteration of vascular anomalies associated with ICH, vascular neurosurgeons today require a thorough understanding of the various intraoperative imaging modalities available for obtaining real-time information. Use of one or more of these modalities may improve the surgeon’s confidence during the procedure, the patient’s safety during surgery, and surgical outcome.

The modern techniques discussed include 1) indocyanine green–based video angiography, which provides realtime information based on high-quality images showing the residual filling of vascular pathological entities and the patency of blood vessels of any size in the surgical field; and 2) intraoperative angiography, which remains the gold standard intraoperative diagnostic test in the surgical management of cerebral aneurysms and arteriovenous malformations. Hybrid procedures, providing multimodality image-guided surgeries and combining endovascular with microsurgical strategies within the same surgical session, have become feasible and safe. Microdoppler is a safe, noninvasive, and reliable technique for evaluation of hemodynamics of vessels in the surgical field, with the advantage of ease of use. Intraoperative MRI provides an effective navigation tool for cavernoma surgery, in addition to assessing the extent of resection during the procedure. Intraoperative CT scanning has the advantage of very high sensitivity to acute bleeding, thereby assisting in the confirmation of the extent of hematoma evacuation and the extent of vascular anomaly resection. Intraoperative ultrasound aids navigation and evacuation assessment during intracerebral hematoma evacuation surgeries. It supports the concept of minimally invasive surgery and has undergone extensive development in recent years, with the quality of ultrasound imaging having improved considerably.

Image-guided therapy, combined with modern intraoperative imaging modalities, has changed the fundamentals of conventional vascular neurosurgery by presenting real-time visualization of both normal tissue and pathological entities. These imaging techniques are important adjuncts to the surgeon’s standard surgical armamentarium. Familiarity with these imaging modalities may help the surgeon complete procedures with improved safety, efficiency, and clinical outcome

Increased Frameless Stereotactic Accuracy With High-Field Intraoperative Magnetic Resonance Imaging

Captura de pantalla 2012-12-23 a la(s) 11.07.11 

Neurosurgery 71[ONS Suppl 2]:ons321–ons328, 2012

Frameless stereotaxy commonly registers preoperative magnetic resonance imaging (MRI) to patients by using surface scalp anatomy or adhesive fiducial scalp markers. Patients’ scalps may shift slightly between preoperative imaging and final surgical positioning with pinion placement, introducing error. This might be reduced when frameless stereotaxy is performed in a high-field intraoperative MRI (iMRI), as patients are positioned before imaging. This could potentially improve accuracy.

OBJECTIVE: To compare frameless stereotactic accuracy using a high-field iMRI with that using standard preoperative MRI.

METHODS: Data were obtained in 32 adult patients undergoing frameless stereotacticguided brain tumor surgery. Stereotactic images were obtained with 1.5T MRI scanner either preoperatively (14 patients) or intraoperative (18 patients). System-generated accuracy measurements and distances from the actual center of each fiducial marker to that represented by neuronavigation were recorded. Finally, accuracy at multiple deep targets was assessed by using a life-sized human head stereotactic phantom in which fiducials were placed on deformable foam to mimic scalp.

RESULTS: System-generated accuracy measurements were significantly better for the iMRI group (mean 6 SEM = 1.04 6 0.05 mm) than for the standard group (1.82 6 0.09 mm; P , .001). Measured distances from the actual center of scalp fiducial markers to that represented by neuronavigation were also significantly smaller for iMRI (1.72 6 0.10 mm) in comparison with the standard group (3.17 6 0.22 mm; P , .001). Deep accuracy in the phantom model was significantly better with iMRI (1.67 6 0.12 mm) than standard imaging (2.28 6 0.14 mm; P = .003).

CONCLUSION: Frameless stereotactic accuracy is increased by using high-field iMRI compared with standard preoperative imaging.

Typical 3-D localization of tumor remnants of WHO grade II hemispheric gliomas—lessons learned from the use of intraoperative high-field MRI control

Acta Neurochir (2011) 153:479–487. DOI 10.1007/s00701-010-0911-3

Complete resection of grade II gliomas might prolong survival but is not always possible. The goal of the study was to evaluate the location of unexpected grade II gliomas remnants after assumed complete removal with intraoperative (iop) MRI and to assess the reason for their non-detection.

Methods Intraoperative MR images of 35 patients with hemispheric grade II gliomas, acquired after assumed complete removal of preoperatively segmented tumor/ tumor part, were studied for existence of unexpected tumor remnants. Remnants location was classified in relation to tumor cavity in axial and vertical planes. The relation of remnants to retractor position and to surgeons’ visual axis, and the role of neuronavigational accuracy and brain shift, was assessed.

Results Unexpected remnants were found in 16 patients (46%). In 29.2%, the reason was loss of neuronavigational accuracy. In 21%, remnants were in that part of the resection cavity, where the retractor had been placed initially. In 17%, they were deeply located and hidden by the retractor. In 13%, remnants were hidden by the overlapping brain; and in 21%, the reason was not obvious. In 75% of all temporomesial tumors, remnants were posterolateral to the resection cavity. Remnants detection with iopMRI and update of neuronavigational data allowed further removal in 14 of 16 cases. In two cases, remnant location precluded their removal.

Conclusions Distribution of tumor remnants of grade II gliomas tends to follow some patterns. Targeted attention to the areas of possible remnants could increase the radicality of surgery, even if intraoperative imaging is not performed.