Optimized angiographic computed tomography with intravenous contrast injection: an alternative to conventional angiography in the follow-up of clipped aneurysms?

J Neurosurg 117:29–36, 2012

The purpose of this study was to evaluate the diagnostic accuracy of an optimized angiographic CT (ACT) program with intravenous contrast agent injection (ivACT) in the assessment of potential aneurysm remnants after neurosurgical clipping compared with conventional digital subtraction angiography (DSA).

Methods. The authors report on 14 patients with 19 surgically clipped cerebral aneurysms who were scheduled to undergo angiographic follow-up. For each patient, the authors performed ivACT with dual rotational acquisition and conventional angiography including a 3D rotational run. The ivACT and 3D DSA data were reconstructed with different imaging modes, including a newly implemented subtraction mode with motion correction. Thereafter, the data sets were merged by the dual-volume technique, and freely rotatable 3D images were obtained for further analysis. Observed aneurysm remnants were electronically measured and classified for each modality by 2 experienced neuroradiologists.

Results. Digital subtraction angiography and ivACT both provided high-quality images without motion artifacts. Artifact disturbances from the aneurysm clips led to a compromised, but still sufficient, image quality in 1 case. The ivACT assessed all aneurysm remnants as true-positive up to a minimal size of 2.6 × 2.4 mm in accordance with the DSA findings. There was a tendency for ivACT to overestimate the size of the aneurysm remnants. All cases without aneurysm remnants on DSA were scored correctly as true-negative by ivACT.

Conclusions. By using an optimized image acquisition protocol as well as enhanced postprocessing algorithms, the noninvasive ivACT seems to achieve results comparable to those of conventional angiography in the follow-up of clipped cerebral aneurysms. The authors have shown that ivACT can provide reliable diagnostic information about potential aneurysm remnants after neurosurgical clipping with high sensitivity and specificity, sufficient for clinical decision making, at least for aneurysms in the anterior circulation located distal to the internal carotid artery. These preliminary results may be a promising step to replace conventional angiography by a noninvasive imaging technique in selected cases after aneurysm clipping.

 

Anterior Cervical Reconstruction With Pedicle Screws After a 4-Level Corpectomy

Spine 2012 ; 37 : E927 – E930

Anterior reconstruction after multilevel corpectomy is a challenging technique, and there are many reports on its complications. Graft dislodgement is one of the major complications after long cervical fusion. The main cause of failure seems to be a lack of stability in the conventional reconstruction technique. However, pedicle screws for posterior cervical reconstruction show remarkable stability. We describe a new technique of anterior cervical reconstruction with pedicle screws and fibular strut grafting.

Methods. Seven patients with multilevel cervical myelopathy were treated with this new reconstruction technique after a 4-level corpectomy. We describe this new technique and review the patients’ clinical history, results of radiographical imaging, and outcomes. Clinical outcomes were assessed preoperatively and at 3 months postoperatively. Postoperative radiographs were assessed 3 months and 6 months postoperatively.

Results. The mean operative time was 182 minutes and the mean blood loss was 271 mL. The average Japanese Orthopaedic Association score for cervical myelopathy improved from 11.5 points preoperatively to 14.5 points 3 months postoperatively. No patients experienced major complications, such as neurological deterioration, infection, or massive blood loss. There was no case of reconstruction failure, graft dislodgement, migration, or screw displacement.

Conclusion. To our knowledge, this is the first description of an anterior cervical reconstruction approach, using pedicle screws and fibular strut grafting after a 4-level corpectomy. It is likely that this technique will result in better clinical outcomes with fewer complications in the treatment of patients with multilevel cervical myelopathy.