Prognostic Factors for Satisfaction After Decompression Surgery for Lumbar Spinal Stenosis

Neurosurgery 82:645–651, 2018

Surgical treatment for lumbar spinal stenosis is associated with both short- and long-term benefits with improvements in patient function and pain. Even though most patients are satisfied postoperatively, some studies report that up to onethird of patients are dissatisfied.

OBJECTIVE: To present clinical outcome data and identify prognostic factors related to patient satisfaction 1 yr after posterior decompression surgery for lumbar spinal stenosis.

METHODS: This multicenter register study included 2562 patients. Patients were treated with various types of posterior decompression. Patients with previous spine surgery or concomitant fusion were excluded. Patient satisfaction was analyzed for associations with age, sex, body mass index, smoking status, duration of pain, number of decompressed vertebral levels, comorbidities, and patient-reported outcome measures,which were used to quantify the effect of the surgical intervention.

RESULTS: At 1-yr follow-up, 62.4% of patients were satisfied but 15.1% reported dissatisfaction. The satisfied patients showed significantly greater improvement in all outcome measures compared to the dissatisfied patients. The outcome scores for the dissatisfied patients were relatively unchanged or worse compared to baseline. Association was seen between dissatisfaction, duration of leg pain, smoking status, and patient comorbidities. Patients with good walking capacity at baseline were less prone to be dissatisfied compared to patients with poor walking capacity.

CONCLUSION: This study found smoking, long duration of leg pain, and cancerous and neurological disease to be associated with patient dissatisfaction, whereas good walking capacity at baseline was positively associated with satisfaction after 1 yr.

“Birdlime” technique using TachoSil tissue sealing sheet soaked with fibrin glue for sutureless vessel transposition in microvascular decompression

J Neurosurg 128:1522–1529, 2018

Microvascular decompression (MVD) is effective for the treatment of trigeminal neuralgia (TN), hemifacial spasm (HFS), and glossopharyngeal neuralgia. The transposition technique is the standard procedure to avoid adhesions and granuloma around the decompression site but is more complex and difficult to perform than the interposition technique. The authors describe a simple and safe MVD transposition procedure they call the “birdlime” technique, which uses a tissue glue–coated collagen sponge soaked with fibrin glue, and the results of this technique.

METHODS The authors retrospectively reviewed the medical charts and radiographic findings of 27 consecutive patients with TN (8 patients) and HFS (19 patients) who, between January 2012 and December 2015, had undergone an MVD transposition procedure utilizing a tissue glue–coated collagen sponge (TachoSil tissue sealing sheet) soaked with fibrin glue (Tisseel 2-component fibrin sealant, vapor heated). Offending arteries among the patients with TN were the superior cerebellar artery (SCA) in 5 patients, the SCA and anterior inferior cerebellar artery (AICA) in 2, and the AICA in 1. Those among the patients with HFS were the vertebral artery (VA) in 3 patients, the VA and AICA in 4, the VA and posterior inferior cerebellar artery (PICA) in 3, the PICA in 4, the AICA in 1, the AICA-PICA in 3, and the PICA and AICA in 1. Operations were performed according to the Jannetta procedure. The offending artery was transposed and fixed to the dura mater of the petrous bone using TachoSil pieces soaked with fibrin glue. Postoperative constructive interference in steady-state MRI was performed to evaluate the change in the position of the offending artery.

RESULTS Transposition of the offending artery was easily and safely performed in all patients. All patients had total remission of symptoms directly after the procedure. No severe complications occurred. The postoperative course was uneventful. No recurrences, adhesions, or dysfunction of the cranial nerves was observed in any of the patients. Postoperative MRI showed that the offending vessels were displaced and fixed in the appropriate position.

CONCLUSIONS The described transposition technique provides an easy and adjustable way to perform MVD safely and effectively. In addition, this transposition and fixation technique is simple and avoids the risk of needle injury close to the cranial nerves and vessels. This simple sutureless technique is recommended for MVD to reduce the risk of intraoperative neurovascular injury.

 

Circumferential Wall Enhancement on Magnetic Resonance Imaging is Useful to Identify Rupture Site in Patients with Multiple Cerebral Aneurysms

Neurosurgery 82:638–644, 2018

Identification of rupture sites in patients with multiple intracranial aneurysms is largely based on aneurysmsize, location, and shape. Finding circumferential enhancement along the aneurysm wall (CEAW) on magnetic resonance (MR) vessel wall imaging was recently shown to be indicative of ruptured aneurysm.

OBJECTIVE: To investigate the hypothesis that a higher degree of CEAW would identify the site of rupture in patients with multiple aneurysms.

METHODS: We prospectively performed quantitative analysis of CEAW in consecutive patients with both aneurysmal subarachnoid hemorrhage and multiple aneurysms (26 patientswith a total of 62 aneurysms), usingMR vesselwall imaging. Three-dimensional T1-weighted fast spin-echo sequenceswere obtained before and after injection of contrast media, and the wall enhancement index (WEI) was calculated. Aneurysm characteristics (size, location, irregular shape, aspect ratio [neck-to-dome length/neck width], and WEI) were compared between ruptured and unruptured aneurysms. Odds ratios with 95% confidence intervals for ruptures were calculated with conditional univariable logistic regression analysis. Analyses were repeated after adjustment for aneurysm size.

RESULTS: Large aneurysm size, high aspect ratio, WEI (above the median values), and irregular shape were significantly associated with aneurysm rupture. After adjustment for aneurysm size, WEI (adjusted odds ratio: 8.8; 95% confidence interval, 1.1-72.6) as well as irregular shape and aspect ratio showed a strong association with rupture.

CONCLUSION: CEAW is associated with rupture of intracranial aneurysm independent of aneurysm size and patient characteristics. Contrast-enhanced MR vessel wall imaging helps to identify the site of rupture in patients with multiple aneurysms.