Do expandable cage size and number of cages matter in transforaminal lumbar interbody fusion at L5–S1?

J Neurosurg Spine 41:209–215, 2024

Expandable transforaminal lumbar interbody fusion (TLIF) cages were designed to address the limitations of static cages. Bilateral cage insertion can potentially enhance stability, fusion rates, and segmental lordosis. However, the benefits of unilateral versus bilateral expandable cages with varying sizes in TLIF remain unclear. This study used a validated finite element spine model to compare the biomechanical properties of L5–S1 TLIF by using differently sized expandable cages inserted unilaterally or bilaterally.

METHODS A finite element model of X-PAC expandable lumbar cages was created and used at the L5–S1 level. This model had cage dimensions of 9 mm in height, 15° in lordosis, and varying widths and lengths. Various placements (unilateral vs bilateral) and sizes were examined under pure moment loading to evaluate range of motion, adjacent-segment motion, and endplate stress.

RESULTS Stability at the L5–S1 level decreased when smaller cages were used in both the unilateral and bilateral cage models. In the unilateral model, cage 1 (the smallest cage) resulted in 47.9% more motion at the L5–S1 level compared to cage 5 (the largest cage) in flexion, as well as 64.8% more motion in extension. Similarly, in the bilateral TLIF model, bilateral cage 1 led to 49.4% more motion at the L5–S1 level in flexion and 73.4% more motion in extension compared to bilateral cage 5. Unilateral insertion of cage 5 provided superior stability in flexion and surpassed cages 1–3 in extension when compared to cages inserted either unilaterally or bilaterally. Reduced motion at L5–S1 correlated with increased adjacent-segment motion at L4–5. Bilateral TLIF resulted in greater adjacent-segment motion compared to unilateral TLIF with the same-size cages. Inferior endplates experienced higher stress during flexion and extension than superior endplates, with this difference being more pronounced in the bilateral model. In bilateral cage placement, stress differences ranged from 46.3% to 60.0%, while they ranged from 1.1% to 9.6% in unilateral cages. Qualitative analysis revealed increased focal stress in unilateral cages versus bilateral cages.

CONCLUSIONS The authors’ study shows that using a large unilateral TLIF cage may offer better stability than the bilateral insertion of smaller cages. While large bilateral cages increase adjacent-segment motion, they also provide a uniform stress distribution on the endplates. These findings deepen our understanding of the biomechanics of the available expandable TLIF cages.

Correlation between the spinopelvic type and morphological characteristics of lumbar facet joints in degenerative lumbar spondylolisthesis

J Neurosurg Spine 38:425–435, 2023

The correlation between the spinopelvic type and morphological characteristics of lumbar facet joints in patients with degenerative lumbar spondylolisthesis (DLS) was investigated.

METHODS One hundred forty-two patients with L4 DLS were enrolled (DLS group), and 100 patients with lumbar disc herniation without DLS were selected as the control group (i.e., non–lumbar spondylolisthesis [NL] group). Morphological parameters of L4–5 facet joints and L4–5 disc height and angle were measured on 3D reconstructed CT images; namely, the facet joint angle (FJA), pedicle–facet joint angle (PFA), facet joint tropism, and facet joint osteoarthritis (OA). The L4 slip percentage, sacral slope, and lumbar lordosis were measured on radiographs. Patients in the DLS and NL groups were divided into 4 subgroups according to Roussouly classification (types I, II, III, and IV).

RESULTS In the DLS and NL groups, as the spinopelvic type changed from type II to type IV, the facet joint morphology showed a gradual sagittal orientation in the FJA, a gradual horizontal orientation in the PFA, a gradual severity in OA, and a gradual increase in the slip percentage, but changes were completely opposite from type I to type II. Additionally, compared with the NL group, the facet joint morphology in the DLS group had more horizontal orientation in PFA, more sagittal orientation in the FJA, and the facet joint tropism and OA were more severe.

CONCLUSIONS Facet joint morphology was correlated with spinopelvic type in the slip segment of DLS. Facet joint morphology was part of the joint configuration in different spinopelvic types, not just the result of joint remodeling after DLS. Moreover, morphological changes of the facet joints and DLS interacted with each other. Additionally, morphological remodeling of the facet joints in DLS played an important role in spinal balance and should be taken into consideration when designing a surgical approach.

Occipitocervical Instability After Far-Lateral Transcondylar Surgery

Neurosurgery 80:140–145, 2017

After a far-lateral transcondylar approach, patients may maintain neutral alignment in the immediate postoperative period, but severe occipitoatlantal subluxation may occur gradually with cranial settling and possible neurological injury. Previous research is based on assumptions regarding the extent of condylar resection and the change in biomechanics that produces instability.

OBJECTIVE: To quantify the extent of bone removal during a far-lateral transcondylar approach, determine the changes in range of motion (ROM) and stiffness that occur after condylar resection, and identify the threshold of condylar resection that predicts alterations in occipitocervical biomechanics.

METHODS: Nine human cadaveric specimens were biomechanically tested before and after far-lateral transcondylar resection extending into the hypoglossal canal (HC). The extent of condylar resection was quantified using volumetric comparison between pre- and postresection computed tomography scans. ROM and stiffness testing were performed in intact and resected states. The extent of resection that produced alterations in occipitocervical biomechanics was assessed with sensitivity analysis.

RESULTS: Bone removal during condylar resection into the HC was 15.4%-63.7% (mean 35.7%). Sensitivity analysis demonstrated that changes in biomechanics may occur when just 29% of the occipital condyle was resected (area under the curve 0.80-1.00).

CONCLUSION: Changes in occipitocervical biomechanics may be observed if one-third of the occipital condyle is resected. During surgery, the HC may not be a reliable landmark to guide the extent of resection. Patients who undergo condylar resections extending into or beyond the HC require close surveillance for occipitocervical instability.

New Posterior Atlantoaxial Restricted Non-Fusion Fixation for Atlantoaxial Instability

New Posterior Atlantoaxial Restricted Non-Fusion Fixation for Atlantoaxial Instability

Neurosurgery 78:735–741, 2016

Loss of axial rotation and lateral bending after atlantoaxial fusion reduces a patient’s quality of life. Therefore, effective, nonfusion fixation alternatives are needed for atlantoaxial instability.

OBJECTIVE: To evaluate the initial stability and function of posterior atlantoaxial restricted nonfusion fixation (PAARNF), a new protocol, using cadaveric cervical spines compared with the intact state, destabilization, and posterior C1-C2 rod fixation.

METHODS: Cervical areas C0 through C3 were used from 6 cadaveric spines to test flexion-extension, lateral bending, and axial rotation range of motion (ROM). With the use of a machine, 1.5-Nm torque at a rate of 0.1 Nm/s was used and held for 10 seconds. The specimens were loaded 3 times, and data were collected in the third cycle and tested in the following sequence: (1) intact, (2) destabilization (using a type II odontoid fracture model), (3) destabilization with PAARNF (PAARNF group), and (4) rod implantation (rod group). The order of tests for the PAARNF and rod groups was randomly assigned.

RESULTS: The average flexion-extension ROM in the PAARNF group was 7.44 6 2.05, which was significantly less than in the intact (P = .00) and destabilization (P = .00) groups but not significantly different from that of the rod group (P = .07). The average lateral bending ROM (10.59 6 2.33; P = .00) and axial rotation ROM (38.79 6 13.41; P = .00) of the PAARNF group were significantly greater than in the rod group. However, the values of the PAARNF group showed no significant differences compared with those of the intact group.

CONCLUSION: PAARNF restricted atlantoaxial flexion-extension but preserved axial rotation and lateral bending at the atlantoaxial joint in a type II odontoid fracture model. However, it should not be used clinically until further studies have been performed to test the long-term effects of this procedure.

The role of sacral slope in lumbosacral fusion: a biomechanical study

sacral slope in LS fusion

J Neurosurg Spine 23:754–762, 2015

Abnormal sacral slope (SS) has shown to increase progression of spondylolisthesis, yet there exists a paucity in biomechanical studies investigating its role in the correction of adult spinal deformity, its influence on lumbosacral shear, and its impact on the instrumentation selection process. This in vitro study investigates the effect of SS on 3 anterior lumbar interbody fusion constructs in a biomechanics laboratory.

Methods Nine healthy, fresh-frozen, intact human lumbosacral vertebral segments were tested by applying a 550- N axial load to specimens with an initial SS of 20° on an MTS Bionix test system. Testing was repeated as SS was increased to 50°, in 10° increments, through an angulated testing fixture. Specimens were instrumented using a standalone integrated spacer with self-contained screws (SA), an interbody spacer with posterior pedicle screws (PPS), and an interbody spacer with anterior tension band plate (ATB) in a randomized order. Stiffness was calculated from the linear portion of the load-deformation curve. Ultimate strength was also recorded on the final construct of all specimens (n = 3 per construct) with SS of 40°.

Results Axial stiffness (N/mm) of the L5–S1 motion segment was measured at various angles of SS: for SA 292.9 ± 142.8 (20°), 277.2 ± 113.7 (30°), 237.0 ± 108.7 (40°), 170.3 ± 74.1 (50°); for PPS 371.2 ± 237.5 (20°), 319.8 ± 167.2 (30°), 280.4 ± 151.7 (40°), 233.0 ± 117.6 (50°); and for ATB 323.9 ± 210.4 (20°), 307.8 ± 125.4 (30°), 249.4 ± 126.7 (40°), 217.7 ± 99.4 (50°). Axial compression across the disc space decreased with increasing SS, indicating that SS beyond 40° threshold shifted L5–S1 motion into pure shear, instead of compression-shear, defining a threshold. Trends in ultimate load and displacement differed from linear stiffness with SA > PPS > ATB.

Conclusions At larger SSs, bilateral pedicle screw constructs with spacers were the most stable; however, none of the constructs were significantly stiffer than intact segments. For load to failure, the integrated spacer performed the best; this may be due to angulations of integrated plate screws. Increasing SS significantly reduced stiffness, which indicates that surgeons need to consider using more aggressive fixation techniques.

Traumatic Brain Injuries: The Influence of the Direction of Impact

Traumatic Brain Injuries- The Influence of the Direction of Impact

Neurosurgery 76:81–91, 2015

Head impact direction has been identified as an influential risk factor in the risk of traumatic brain injury (TBI) from animal and anatomic research; however, to date, there has been little investigation into this relationship in human subjects. If a susceptibility to certain types of TBI based on impact direction was found to exist in humans, it would aid in clinical diagnoses as well as prevention methods for these types of injuries.

OBJECTIVE: To examine the influence of impact direction on the presence of TBI lesions, specifically, subdural hematomas, subarachnoid hemorrhage, and parenchymal contusions.

METHODS: Twenty reconstructions of falls that resulted in a TBI were conducted in a laboratory based on eyewitness, interview, and medical reports. The reconstructions involved impacts to a Hybrid III anthropometric dummy and finite element modeling of the human head to evaluate the brain stresses and strains for each TBI event.

RESULTS: The results showed that it is likely that increased risk of incurring a subdural hematoma exists from impacts to the frontal or occipital regions, and parenchymal contusions from impacts to the side of the head. There was no definitive link between impact direction and subarachnoid hemorrhage. In addition, the results indicate that there is a continuum of stresses and strain magnitudes between lesion types when impact location is isolated, with subdural hematoma occurring at lower magnitudes for frontal and occipital region impacts, and contusions lower for impacts to the side.

CONCLUSION: This hospital data set suggests that there is an effect that impact direction has on TBI depending on the anatomy involved for each particular lesion.

Robotics and the spine: a review of current and ongoing applications

Virtual_Reality_and_Robotics_in

Neurosurg Focus 36 (3):E10, 2014

Robotics in the operating room has shown great use and versatility in multiple surgical fields. Robotassisted spine surgery has gained significant favor over its relatively short existence, due to its intuitive promise of higher surgical accuracy and better outcomes with fewer complications. Here, the authors analyze the existing literature on this growing technology in the era of minimally invasive spine surgery.

Methods. In an attempt to provide the most recent, up-to-date review of the current literature on robotic spine surgery, a search of the existing literature was conducted to obtain all relevant studies on robotics as it relates to its application in spine surgery and other interventions.

Results. In all, 45 articles were included in the analysis. The authors discuss the current status of this technology and its potential in multiple arenas of spinal interventions, mainly spine surgery and spine biomechanics testing.

Conclusions. There are numerous potential advantages and limitations to robotic spine surgery, as suggested in published case reports and in retrospective and prospective studies. Randomized controlled trials are few in number and show conflicting results regarding accuracy. The present limitations may be surmountable with future technological improvements, greater surgeon experience, reduced cost, improved operating room dynamics, and more training of surgical team members. Given the promise of robotics for improvements in spine surgery and spine biomechanics testing, more studies are needed to further explore the applicability of this technology in the spinal operating room. Due to the significant cost of the robotic equipment, studies are needed to substantiate that the increased equipment costs will result in significant benefits that will justify the expense.

Axial Spondylectomy and Circumferential Reconstruction via a Posterior Approach

Axial spondylectomy

Neurosurgery 72:300–309, 2013

Spinal metastases of the second cervical vertebra are a subset of tumors that are particularly difficult to address surgically. Previously described techniques require highly morbid circumferential dissection posterior to the pharynx for resection and reconstruction.

OBJECTIVE: To perform a biomechanical analysis of instrumented reconstruction configurations used after axial spondylectomy and to demonstrate safe use of a novel construct in a patient case report.

METHODS: Several different published and novel reconstruction configurations were inserted into 7 occipitocervical spines that underwent axial spondylectomy. A biomechanical analysis of the stiffness of the constructs in flexion and extension, lateral bending, and rotation was performed. A patient then underwent a posterior-only approach for axial spondylectomy and circumferential reconstruction.

RESULTS: Biomechanical analysis of different constructs demonstrated that anterior column reconstruction with bilateral cages spanning the C1 lateral mass to the C3 facet in combination with occipitocervical instrumentation was superior in flexion-extension and equivalent in lateral bending and rotation to currently used constructs. The patient in whom this construct was placed via a posterior-only approach for axial spondylectomy and instrumentation remained at neurological baseline and demonstrated no recurrence of local disease or failure of instrumentation to date.

CONCLUSION: When C1 lateral mass to C3 facet bilateral cage plus occipitocervical instrumentation is compared with existing anterior and posterior constructs, this novel reconstruction is biomechanically equivalent if not superior in performance. In a patient, the posterior-only approach for C2 spondylectomy with the novel reconstruction was safe and durable and avoided the morbidity of the anterior approach.