Retrospective comparison of long‑term functionality and revision rate of two different shunt valves in pediatric and adult patients

Acta Neurochirurgica (2023) 165:2541–2549

The most frequent therapy of hydrocephalus is implantation of ventriculoperitoneal shunts for diverting cerebrospinal into the peritoneal cavity. We compared two adjustable valves, proGAV and proGAV 2.0, for complications resulting in revision surgery.

Methods Four hundred patients undergoing primary shunt implantation between 2014 and 2020 were analyzed for overall revision rate, 1-year revision rate, and revision-free survival observing patient age, sex, etiology of hydrocephalus, implantation site, prior diversion of cerebrospinal fluid, and cause of revision.

Results All data were available of all 400 patients (female/male 208/192). Overall, 99 patients underwent revision surgery after primary implantation. proGAV valve was implanted in 283 patients, and proGAV 2.0 valves were implanted in 117 patients. There was no significant difference between the two shunt valves concerning revision rate (p = 0.8069), 1-year revision rate (p = 0.9077), revision-free survival (p = 0.6921), and overall survival (p = 0.3232). Regarding 1-year revision rate, we observed no significant difference between the two shunt valves in pediatric patients (40.7% vs 27.6%; p = 0.2247). Revision operation had to be performed more frequently in pediatric patients (46.6% vs 24.8%; p = 0.0093) with a significant higher number of total revisions with proGAV than proGAV 2.0 (33 of 59 implanted shunts [55.9%] vs. 8 of 29 implanted shunts [27.6%]; p = 0.0110) most likely due to longer follow-up in the proGAV-group. For this reason, we clearly put emphasis on analyzing results regarding 1-year revision rate.

Conclusion According to the target variables we analyzed, aside from lifetime revision rate in pediatric patients, there is no significant difference between the two shunt valves.

Strategies for Computed Tomography Radiation Dose Reduction in Pediatric Neuroimaging

Strategies for Computed Tomography Radiation Dose Reduction in Pediatric Neuroimaging

Neurosurgery 77:228–232, 2015

Radiation exposure from diagnostic imaging is a significant concern, particularly in the care of pediatric patients. Computed tomography (CT) scanning is a significant source of radiation.

OBJECTIVE: To demonstrate that diagnostic quality CT images can be obtained while minimizing the effective radiation dose to the patient.

METHODS: In this retrospective cross-sectional study, noncontrast head CT scan data were reviewed, and indications for scans and estimated radiation dose delivered were recorded. The estimated effective radiation dose (EERD) for each CT protocol was reviewed.

RESULTS: We identified 251 head CT scans in a single month. Of these, 96 scans were using a low-dose shunt protocol with a mean EERD of 0.82 mSv. The remaining 155 scans were performed using the standard protocol, and the mean EERD was 1.65 mSv. Overall, the EERD was minimized while maintaining diagnostic scan quality.

CONCLUSION: Although replacing a CT with magnetic resonance imaging is ideal to completely avoid ionizing radiation, this is not always practical or preferred. Therefore, it is important to have CT protocols in place that minimize radiation dose without sacrificing diagnostic quality. The protocols in place at our institution could be replicated at other academic and community hospitals and imaging centers.