Bilateral subthalamic deep brain stimulation using single track microelectrode recording

Acta Neurochir (2011) 153:1087–1095 DOI 10.1007/s00701-011-0953-1

Microelectrode recording (MER) is widely used during deep brain stimulation (DBS) procedures because MER can identify structural borders and eloquent structures, localize somatotopic arrangements, and provide an outline of the three-dimensional shapes of target nuclei. However, MER may cause intracranial hemorrhage. We performed single track MER during DBS procedures, analyzed the accuracy of electrode positioning with MRI, and compared the amount of air and the potential risk of intracranial hemorrhage.

Method A total of 46 electrodes were placed in 23 patients who suffered from advanced Parkinson’s disease and who underwent bilateral subthalamic nucleus DBS using single track MER. Each patient’s Unified Parkinson’s Disease Rating Scale (UPDRS) score and levo-dopa equivalent dosage (LED) were estimated pre- and postoperatively. The accuracy of electrode positioning and fontal air thickness was measured by a pre- or postoperative magnetic resonance imaging (MRI) merging technique.

Findings The mean electrode positioning error was 0.92 mm (0.3–2.94 mm). The mean frontal air thickness on postoperative MRI was 3.85 mm (0–10.3 mm), which did not affect the electrode accuracy statistically (p=0.730). A total of nine electrodes required repositioning after single-track MER because they affected microstimulation or because an abnormally short STN length was observed during MER. In this series, one patient suffered from an intracranial hemorrhage after surgery that appeared to be due to venous infarction rather than related to MER.

Conclusions Although MER can facilitate accurate positioning of electrodes, multi-track MER may increase the risk of intracranial hemorrhage. The accuracy of electrode positioning appears to be acceptable under single track MER during STN DBS with careful electrophysiological and neurological monitoring. The risk of intracranial hemorrhage appears to be minimal, especially in elderly patients with atrophic brains.

Individual Fiber Anatomy of the Subthalamic Region Revealed With Diffusion Tensor Imaging: A Concept to Identify the Deep Brain Stimulation Target for Tremor Suppression

Neurosurgery 68:1069–1076, 2011 DOI: 10.1227/NEU.0b013e31820a1a20

Deep brain stimulation (DBS) has been proven to alleviate tremor of various origins. Distinct regions have been targeted. One explanation for good clinical tremor control might be the involvement of the dentatorubrothalamic tract (DRT) as has been suggested in superficial (thalamic) and inferior (posterior subthalamic) target regions. Beyond a correlation with atlas data and the postmortem evaluation of patients treated with lesion surgery, proof for the involvement of DRT in tremor reduction in the living, the scope of this work, is elusive.

OBJECTIVE: To report a case of unilateral refractory tremor in tremor-dominant Parkinson disease treated with thalamic DBS.

METHODS: Preoperative diffusion tensor imaging (DTI) was performed. Correlation with individual DBS electrode contact locations was obtained through postoperative fusion of helical computed tomography (CT) data with DTI fiber tracking.

RESULTS: Tremor was alleviated effectively. An evaluation of the active electrode contact position revealed clear involvement of the DRT in tremor control. A closer evaluation of clinical effects and side effects revealed a highly detailed individual fiber map of the subthalamic region with DTI fiber tracking.

CONCLUSION: This is the first time the involvement of the DRT in tremor reduction through DBS has been shown in the living. The combination of DTI with postoperative CT and the evaluation of the electrophysiological environment of distinct electrode contacts led to an individual detailed fiber map and might be extrapolated to refined DTI-based targeting strategies in the future. Data acquisition for a larger study group is the topic of our ongoing research.

Intraoperative Computed Tomography for Deep Brain Stimulation Surgery: Technique and Accuracy Assessment

Neurosurgery 68[ONS Suppl 1]:ons114–ons124, 2011. DOI: 10.1227/NEU.0b013e31820781bc

The efficacy of deep brain stimulation (DBS) is highly dependent on the accuracy of lead placement.

OBJECTIVE: To describe the use of intraoperative computed tomography (iCT) to confirm lead location before surgical closure and to study the accuracy of this technique.

METHODS: Fifteen patients underwent awake microelectrode-guided DBS surgery in a stereotactic frame. A portable iCT scanner (Medtronic O-arm) was positioned around the patient’s head throughout the procedure and was used to confirm lead location before fixation of the lead to the skull. Images were computationally fused with preoperative magnetic resonance imaging (MRI), and lead tip coordinates with respect to the midpoint of the anterior commissure-posterior commissure line were measured. Tip coordinates were compared with those obtained from postoperative MRI.

RESULTS: iCT was integrated into standard frame-based microelectrode-guided DBS surgery with a minimal increase in surgical time or complexity. Technically adequate 2-dimensional and 3-dimensional images were obtained in all cases. Head positioning and fixation techniques that allow unobstructed imaging are described. Lead tip measurements on iCT fused with preoperative MRI were statistically indistinguishable from those obtained with postoperative MRI.

CONCLUSION: iCT can be easily incorporated into standard DBS surgery, replaces the need for C-arm fluoroscopy, and provides accurate intraoperative 3-dimensional confirmation of electrode tip locations relative to preoperative images and surgical plans. iCT fused to preoperative MRI may obviate the need for routine postoperative MRI in DBS surgery. Technical nuances that must be mastered for the efficient use of iCT during DBS implantation are described.

An Assessment of Current Brain Targets for Deep Brain Stimulation Surgery With Susceptibility- Weighted Imaging at 7 Tesla

Neurosurgery 67:1745–1756, 2010 DOI: 10.1227/NEU.0b013e3181f74105

Deep brain stimulation (DBS) surgery is used for treating movement disorders, including Parkinson disease, essential tremor, and dystonia. Successful DBS surgery is critically dependent on precise placement of DBS electrodes into target structures. Frequently, DBS surgery relies on normalized atlas-derived diagrams that are superimposed on patient brain magnetic resonance imaging (MRI) scans, followed by microelectrode recording and macrostimulation to refine the ultimate electrode position. Microelectrode recording carries a risk of hemorrhage and requires active patient participation during surgery.

OBJECTIVE: To enhance anatomic imaging for DBS surgery using high-field MRI with the ultimate goal of improving the accuracy of anatomic target selection.

METHODS: Using a 7-T MRI scanner combined with an array of acquisition schemes using multiple image contrasts, we obtained high-resolution images of human deep nuclei in healthy subjects.

RESULTS: Superior image resolution and contrast obtained at 7 T in vivo using susceptibility-weighted imaging dramatically improved anatomic delineation of DBS targets and allowed the identification of internal architecture within these targets. A patient-specific, 3-dimensional model of each target area was generated on the basis of the acquired images.

CONCLUSION: Technical developments in MRI at 7 T have yielded improved anatomic resolution of deep brain structures, thereby holding the promise of improving anatomicbased targeting for DBS surgery. Future study is needed to validate this technique in improving the accuracy of targeting in DBS surgery.

Bilateral Deep Brain Stimulation for Cervical Dystonia: Long-term Outcome in a Series of 10 Patients

Neurosurgery 67:957–963, 2010 DOI: 10.1227/NEU.0b013e3181ec49c7

Bilateral globus pallidus internus (GPi) deep brain stimulation (DBS) was shown to be effective in cervical dystonia refractory to medical treatment in several small short-term and 1 long-term follow-up series. Optimal stimulation parameters and their repercussions on the cost/benefit ratio still need to be established.

OBJECTIVE: To report our long-term outcome with bilateral GPi deep brain stimulation in cervical dystonia.

METHODS: The Toronto Western Spasmodic Torticollis Rating Scale was evaluated in 10 consecutive patients preoperatively and at last follow-up. The relationship of improvement in postural severity and pain was analyzed and stimulation parameters noted and compared with those in a similar series in the literature.

RESULTS: The mean (standard deviation) follow-up was 37.6 (16.9) months. Improvement in the total Toronto Western Spasmodic Torticollis Rating Scale score as evaluated at latest follow-up was 68.1% (95% confidence interval: 51.5-84.6). In 4 patients, there was dissociation between posture severity and pain improvement. Prevalently bipolar stimulation settings and high pulse widths and amplitudes led to excellent results at the expense of battery life.

CONCLUSION: Improvement in all 3 subscale scores of the Toronto Western Spasmodic Torticollis Rating Scale with bilateral GPi deep brain stimulation seems to be the rule. Refinement of stimulation parameters might have a significant impact on the cost/ benefit ratio of the treatment. The dissociation of improvement in posture severity and pain provides tangible evidence of the complex nature of cervical dystonia and offers interesting insight into the complex functional organization of the GPi.

Clinical Motor Outcome of Bilateral Subthalamic Nucleus Deep-Brain Stimulation for Parkinson’s Disease Using Image-Guided Frameless Stereotaxy

Neurosurgery 67:1088–1093, 2010 DOI: 10.1227/NEU.0b013e3181ecc887

Image-guided neuronavigation has largely replaced stereotactic frames when precise, real-time anatomic localization is required during neurosurgical procedures. However, some procedures, including placement of deep-brain stimulation (DBS) leads for the treatment of movement disorders, are still performed using frame-based stereotaxy. Despite the demonstration of comparable accuracy between frame-based and ‘‘frameless’’ image-guided approaches, the clinical efficacy of frameless DBS placement has never been reported.

OBJECTIVE: To analyze the outcomes of subthalamic nucleus (STN) DBS using the frameless technique for the treatment of Parkinson’s disease (PD).

METHODS: Of 31 subjects (20 men) with PD for 10 6 4 years, 28 had bilateral STN DBS and 3 had unilateral STN DBS. The Unified Parkinson’s Disease Rating Scale (UPDRS) motor scale (III) and total medication doses were assessed before surgery on and off medication and off medication/ON DBS (off/ON) after 6 to 12 months of STN DBS.

RESULTS: There was a 58% improvement from bilateral STN DBS in the UPDRS III (40 6 16 preoperatively off, 17 6 11 off/ON) 9.6 6 1.9 months after surgery (P , .001). This compared favorably with the published outcomes using the frame-based technique. All motor subscores improved significantly (P , .01). The mean reduction in medication was 50%. No intraoperative complications occurred, but one subject with hypertension died of a delayed hemorrhage postoperatively. Two subjects developed postoperative infections that required lead removal and antibiotics.

CONCLUSIONS: Bilateral STN DBS for PD performed by an experienced team using a frameless approach results in outcomes comparable to those reported with the use of the frame-based technique.

Direct visualization of deep brain stimulation targets in Parkinson disease with the use of 7-tesla magnetic resonance imaging

J Neurosurg 113:639–647, 2010.DOI: 10.3171/2010.3.JNS091385

A challenge associated with deep brain stimulation (DBS) in treating advanced Parkinson disease (PD) is the direct visualization of brain nuclei, which often involves indirect approximations of stereotactic targets. In the present study, the authors compared T2*-weighted images obtained using 7-T MR imaging with those obtained using 1.5- and 3-T MR imaging to ascertain whether 7-T imaging enables better visualization of targets for DBS in PD.

Methods. The authors compared 1.5-, 3-, and 7-T MR images obtained in 11 healthy volunteers and 1 patient with PD.

Results. With 7-T imaging, distinct images of the brain were obtained, including the subthalamic nucleus (STN) and internal globus pallidus (GPi). Compared with the 1.5- and 3-T MR images of the STN and GPi, the 7-T MR images showed marked improvements in spatial resolution, tissue contrast, and signal-to-noise ratio.

Conclusions. Data in this study reveal the superiority of 7-T MR imaging for visualizing structures targeted for DBS in the management of PD. This finding suggests that by enabling the direct visualization of neural structures of interest, 7-T MR imaging could be a valuable aid in neurosurgical procedures.

Best surgical practices: a stepwise approach to the University of Pennsylvania deep brain stimulation protocol

Neurosurg Focus 29 (2):E3, 2010. (DOI: 10.3171/2010.4.FOCUS10103)

Deep brain stimulation (DBS) is the treatment of choice for otherwise healthy patients with advanced Parkinson disease who are suffering from disabling dyskinesias and motor fluctuations related to dopaminergic therapy. As DBS is an elective procedure, it is essential to minimize the risk of morbidity. Further, precision in targeting deep brain structures is critical to optimize efficacy in controlling motor features. The authors have already established an operational checklist in an effort to minimize errors made during DBS surgery. Here, they set out to standardize a strict, step-by-step approach to the DBS surgery used at their institution, including preoperative evaluation, the day of surgery, and the postoperative course. They provide careful instruction on Leksell frame assembly and placement as well as the determination of indirect coordinates derived from MR images used to target deep brain structures. Detailed descriptions of the operative procedure are provided, outlining placement of the stereotactic arc as well as determination of the appropriate bur hole location, lead placement using electrophysiology, and placement of the internal pulse generator. The authors also include their approach to preventing postoperative morbidity. They believe that a strategic, step-by-step approach to DBS surgery combined with a standardized checklist will help to minimize operating room mistakes that can compromise targeting and increase the risk of complication.

Deep brain stimulation of the posteromedial hypothalamus: indications, long-term results, and neurophysiological considerations

Neurosurg Focus 29 (2):E13, 2010. DOI: 10.3171/2010.5.FOCUS1094

The aim of this study was to review the indications for and results of deep brain stimulation (DBS) of the posterior hypothalamus (pHyp) in the treatment of drug-refractory and severe painful syndromes of the face, disruptive and aggressive behavior associated with epilepsy, and below-average intelligence. The preoperative clinical picture, functional imaging studies, and overall clinical results in the literature are discussed.

Methods. All patients underwent stereotactic implantation of deep-brain electrodes within the pHyp. Data from several authors have been collected and reported for each clinical entity, as have clinical results, adverse events, and neurophysiological characteristics of the pHyp.

Results. The percentage of patients with chronic cluster headache who responded to DBS was 50% in the overall reported series. The response rate was 100% for short-lasting unilateral neuralgiform headache attacks with conjunctival injection and tearing and for chronic paroxysmal hemicrania, although only 2 patients and 1 patient, respectively, have been described as having these conditions. None of the 4 patients suffering from refractory neuropathic trigeminal pain benefited from the procedure (0% response rate), whereas all 5 patients (100%) affected with refractory trigeminal neuralgia (TN) due to multiple sclerosis (MS) and undergoing pHyp DBS experienced a significant decrease in pain attacks within the first branch of cranial nerve V. Six (75%) of 8 patients presenting with aggressive behavior and mental retardation benefited from pHyp stimulation; 6 patients were part of the authors’ series and 2 were reported in the literature.

Conclusions. In carefully selected patients, DBS of the pHyp can be considered an effective procedure for the treatment of refractory trigeminal autonomic cephalalgias, aggressive behavior, and MS-related TN in the first trigeminal branch. Only larger and prospective studies along with multidisciplinary approaches (including, by necessity, neuroimaging studies) can lead us to better patient selection that would reduce the rate of nonresponders.

A role of diffusion tensor imaging in movement disorder surgery

Acta Neurochir DOI 10.1007/s00701-010-0742-2

The safe and reversible nature of deep brain stimulation (DBS) has allowed movement disorder neurosurgery to become commonplace throughout the world. Fundamental understanding of individual patient’s anatomy is critical for optimizing the effects and side effects of DBS surgery. Three patients undergoing stereotactic surgery for movement disorders, at the institution’s intraoperative magnetic resonance imaging operating suite, were studied with fiber tractography. Stereotactic targets and fiber tractography were determined on preoperative magnetic resonance imagings using the Schaltenbrand–Wahren atlas for definition in the BrainLab iPlan software (BrainLAB Inc., Feldkirchen, Germany). Subthalamic nucleus, globus pallidus interna, and ventral intermediate nucleus targets were studied. Diffusion tensor imaging parameters used ranged from 2 to 8 mm for volume of interest in the x/y/z planes, fiber length was kept constant at 30 mm, and fractional anisotropy threshold varied from 0.20 to 0.45. Diffusion tensor imaging tractography allowed reliable and reproducible visualization and correlation between frontal eye field, premotor, primary motor, and primary sensory cortices via corticospinal tracts and corticopontocerebellar tracts. There is an apparent increase in the number of cortical regions targeted by the fiber tracts as the region of interest is enlarged. This represents a possible mechanism of the increased effects and side effects observed with higher stimulation voltages. Currently available diffusion tensor imaging techniques allow potential methods to characterize the effects and side effects of DBS. This technology has the potential of being a powerful tool to optimize DBS neurosurgery

Effect of subthalamic deep brain stimulation on postural abnormality in Parkinson disease

J Neurosurg 112:1283–1288, 2010.DOI: 10.3171/2009.10.JNS09917

Parkinson disease (PD) is often accompanied by various postural abnormalities such as camptocormia (bent spine) or Pisa syndrome (lateral flexion). The authors studied the effect of subthalamic nucleus deep brain stimulation (STN DBS) on postural abnormality in patients with PD.

Methods. The authors retrospectively reviewed the clinical course of 18 patients who suffered from significant postural abnormality and underwent bilateral STN DBS. Patients whose preoperative posture score (Unified Parkinson’s Disease Rating Scale III, item 28) was 2 or more in the “medication-on” state were enrolled in this study. Eight patients were considered to have camptocormia, and 10 patients were considered to have so-called Pisa syndrome. Nine patients showed apparent thoracolumbar spinal deformity on radiography. Most patients had significant motor fluctuations from levodopa.

Results. In 13 patients with moderate postural abnormality (score of 2 on item 28), 9 patients improved soon after surgery, but 1 patient relapsed. Two patients improved gradually over a long period after surgery, whereas 2 patients did not improve at all. In 5 patients with severe postural abnormality (score of 3 or 4 on item 28), 2 patients improved slightly in the long-term follow-up period after surgery, but 3 patients did not improve at all.

Conclusions. Postural abnormality in patients with PD could be ameliorated by STN DBS, and therefore surgery should be considered before irreversible spinal deformity develops

Subthalamic nucleus deep brain stimulator placement using high-field interventional magnetic resonance imaging and a skull-mounted aiming device: technique and application accuracy

J Neurosurg 112:479–490, 2010. DOI: 10.3171/2009.6.JNS081161

The authors discuss their method for placement of deep brain stimulation (DBS) electrodes using interventional MR (iMR) imaging and report on the accuracy of the technique, its initial clinical efficacy, and associated complications in a consecutive series of subthalamic nucleus (STN) DBS implants to treat Parkinson disease (PD).

Methods. A skull-mounted aiming device (Medtronic NexFrame) was used in conjunction with real-time MR imaging (Philips Intera 1.5T). Preoperative imaging, DBS implantation, and postimplantation MR imaging were integrated into a single procedure performed with the patient in a state of general anesthesia. Accuracy of implantation was assessed using 2 types of measurements: the “radial error,” defined as the scalar distance between the location of the intended target and the actual location of the guidance sheath in the axial plane 4 mm inferior to the commissures, and the “tip error,” defined as the vector distance between the expected anterior commissure–posterior commissure (AC-PC) coordinates of the permanent DBS lead tip and the actual AC-PC coordinates of the lead tip. Clinical out- come was assessed using the Unified Parkinson’s Disease Rating Scale part III (UPDRS III), in the off-medication

state.Results. Twenty-nine patients with PD underwent iMR imaging–guided placement of 53 DBS electrodes into the STN. The mean (± SD) radial error was 1.2 ± 0.65 mm, and the mean absolute tip error was 2.2 ± 0.92 mm. The tip error was significantly smaller than for STN DBS electrodes implanted using traditional frame-based stereotaxy (3.1 ± 1.41 mm). Eighty-seven percent of leads were placed with a single brain penetration. No hematomas were visible on MR images. Two device infections occurred early in the series. In bilaterally implanted patients, the mean improvement on the UPDRS III at 9 months postimplantation was 60%.

Conclusions. The authors’ technical approach to placement of DBS electrodes adapts the procedure to a standard configuration 1.5-T diagnostic MR imaging scanner in a radiology suite. This method simplifies DBS implantation by eliminating the use of the traditional stereotactic frame and the subsequent requirement for registration of the brain in stereotactic space and the need for physiological recording and patient cooperation. This method has improved accuracy compared with that of anatomical guidance using standard frame-based stereotaxy in conjunction with pre- operative MR imaging.

Deep brain stimulation of the subcallosal cingulate gyrus for depression

J Neurosurg 111:1209–1215, 2009.(DOI: 10.3171/2008.10.JNS08763)

Object. Deep brain stimulation (DBS) of the subcallosal cingulate gyrus (SCG), including Brodmann area 25, is currently being investigated for the treatment of major depressive disorder (MDD). As a potential emerging therapy, optimal target selection within the SCG has still to be determined. The authors compared the location of the electrode contacts in responders and nonresponders to DBS of the SCG and correlated the results with clinical outcome to help in identifying the optimal target within the region. Based on the location of the active contacts used for long-term stimulation in responders, the authors suggest a standardized method of targeting the SCG in patients with MDD.

Methods. Postoperative MR imaging studies of 20 patients with MDD treated with DBS of the SCG were ana- lyzed. The authors assessed the location of the active contacts relative to the midcommissural point and in relation to anatomical landmarks within the medial aspect of the frontal lobe. For this, a grid with 2 main lines was designed, with 1 line in the anterior-posterior and 1 line in the dorsal-ventral axis. Each of these lines was divided into 100 units, and data were converted into percentages. The anterior-posterior line extended from the anterior commissure (AC) to the projection of the anterior aspect of the corpus callosum (CCa). The dorsal-ventral line extended from the inferior portion of the CC (CCi) to the most ventral aspect of the frontal lobe (abbreviated “Fr” for the formula).

Results. Because the surgical technique did not vary across patients, differences in stereotactic coordinates between responders and nonresponders did not exceed 1.5 mm in any axis (x, y, or z). In patients who responded to the procedure, contacts used for long-term stimulation were in close approximation within the SCG. In the anterior- posterior line, these contacts were located within a 73.2 ± 7.7 percentile distance from the AC (with the AC center being 0% and the line crossing the CCa being 100%). In the dorsal-ventral line, active contacts in responders were located within a 26.2 ± 13.8 percentile distance from the CCi (with the CCi edge being 0% and the Fr inferior limit being 100%). In the medial-lateral plane, most electrode tips were in the transition between the gray and white matter of SCG.

Conclusions. Active contacts in patients who responded to DBS were relatively clustered within the SCG. Be- cause of the anatomical variability in the size and shape of the SCG, the authors developed a method to standardize the targeting of this region.


Implantation of Deep Brain Stimulator Electrodes Using Interventional MRI

Philip A. Starr, MD, Alastair J.Martin, PhD, Paul S. Larson, MD

Neurosurgery Clinics of North America

Volume 20, Issue 2, Pages 207-217 (April 2009)

The authors describe a method for placement of deep brain stimulator electrodes using interventional MRI in conjunction with a skull-mounted aiming device (Medtronic Nexframe). This approach adapts the procedure to a standard-configuration 1.5-T diagnostic MRI scanner in a radiology suite. Preoperative imaging, device implantation, and postimplantation MRI are integrated into a single procedure performed under general anesthesia, providing real-time, high-resolution magnetic resonance confirmation of electrode position. The method is conceptually simpler than the current standard technique for deep brain stimulator placement, as it eliminates the stereotactic frame, the subsequent requirement for registration of the brain in stereotactic space, physiologic testing, and the need for patient cooperation. With further technical refinement, the interventional MRI method should improve the accuracy, safety, and speed of deep brain stimulator electrode placement.