Feasibility study for brain biopsies performed with the use of a head-mounted robot

Feasibility study for brain biopsies performed with the use of a head-mounted robotJ Neurosurg 123:737–742, 2015

Frame-based stereotactic interventions are considered the gold standard for brain biopsies, but they have limitations with regard to flexibility and patient comfort because of the bulky head ring attached to the patient. Frameless image guidance systems that use scalp fiducial markers offer more flexibility and patient comfort but provide less stability and accuracy during drilling and biopsy needle positioning. Head-mounted robot–guided biopsies could provide the advantages of these 2 techniques without the downsides. The goal of this study was to evaluate the feasibility and safety of a robotic guidance device, affixed to the patient’s skull through a small mounting platform, for use in brain biopsy procedures.

Methods This was a retrospective study of 37 consecutive patients who presented with supratentorial lesions and underwent brain biopsy procedures in which a surgical guidance robot was used to determine clinical outcomes and technical procedural operability.

Results The portable head-mounted device was well tolerated by the patients and enabled stable drilling and needle positioning during surgery. Flexible adjustments of predefined paths and selection of new trajectories were successfully performed intraoperatively without the need for manual settings and fixations. The patients experienced no permanent deficits or infections after surgery.

Conclusions The head-mounted robot–guided approach presented here combines the stability of a bone-mounted set-up with the flexibility and tolerability of frameless systems. By reducing human interference (i.e., manual parameter settings, calibrations, and adjustments), this technology might be particularly useful in neurosurgical interventions that necessitate multiple trajectories.

Frameless robotically targeted stereotactic brain biopsy

J Neurosurg 116:1002–1006, 2012. (http://thejns.org/doi/abs/10.3171/2012.1.JNS111746)

Frameless stereotactic brain biopsy has become an established procedure in many neurosurgical centers worldwide. Robotic modifications of image-guided frameless stereotaxy hold promise for making these procedures safer, more effective, and more efficient. The authors hypothesized that robotic brain biopsy is a safe, accurate procedure, with a high diagnostic yield and a safety profile comparable to other stereotactic biopsy methods.

Methods. This retrospective study included 41 patients undergoing frameless stereotactic brain biopsy of lesions (mean size 2.9 cm) for diagnostic purposes. All patients underwent image-guided, robotic biopsy in which the Surgi-Scope system was used in conjunction with scalp fiducial markers and a preoperatively selected target and trajectory. Forty-five procedures, with 50 supratentorial targets selected, were performed.

Results. The mean operative time was 44.6 minutes for the robotic biopsy procedures. This decreased over the second half of the study by 37%, from 54.7 to 34.5 minutes (p < 0.025). The diagnostic yield was 97.8% per procedure, with a second procedure being diagnostic in the single nondiagnostic case. Complications included one transient worsening of a preexisting deficit (2%) and another deficit that was permanent (2%). There were no infections.

Conclusions. Robotic biopsy involving a preselected target and trajectory is safe, accurate, efficient, and comparable to other procedures employing either frame-based stereotaxy or frameless, nonrobotic stereotaxy. It permits biopsy in all patients, including those with small target lesions. Robotic biopsy planning facilitates careful preoperative study and optimization of needle trajectory to avoid sulcal vessels, bridging veins, and ventricular penetration.