Preemptive strategies and lessons learned from complications encountered with microvascular decompression for hemifacial spasm

J Neurosurg 140:248–259, 2024

OBJECTIVE Microvascular decompression (MVD) is the only curative treatment modality for hemifacial spasm (HFS). Although generally considered to be safe, this surgical procedure is surrounded by many risks and possible complications. The authors present the spectrum of complications that they met in their case series, the possible causes, and the strategies recommended to minimize them.

METHODS The authors reviewed a prospectively maintained database for MVDs performed from 2005 until 2021 and extracted relevant data including patient demographics, offending vessel(s), operative technique, outcome, and different complications. Descriptive statistics with uni- and multivariable analyses for the factors that may influence the seventh, eighth, and lower cranial nerves were performed.

RESULTS Data from 420 patients were obtained. Three hundred seventeen of 344 patients (92.2%) with a minimum follow-up of 12 months had a favorable outcome. The mean follow-up (standard deviation) was 51.3 ± 38.7 months. Immediate complications reached 18.8% (79/420). Complications persisted in only 7.14% of patients (30/420) including persistent hearing deficits (5.95%) and residual facial palsy (0.95%). Temporary complications included CSF leakage (3.10%), lower cranial nerve deficits (3.57%), meningitis (0.71%), and brainstem ischemia (0.24%). One patient died because of herpes encephalitis. Statistical analyses showed that the immediate postoperative disappearance of spasms and male gender are correlated with postoperative facial palsy, whereas combined vessel compressions involving the vertebral artery (VA) and anterior inferior cerebellar artery can predict postoperative hearing deterioration. VA compressions could predict postoperative lower cranial nerve deficits.

CONCLUSIONS MVD is safe and effective for treating HFS with a low rate of permanent morbidity. Proper patient positioning, sharp arachnoid dissection, and endoscopic visualization under facial and auditory neurophysiological monitoring are the key points to minimize the rate of complications in MVD for HFS.

 

Results of a Prospective Randomized Study Comparing a Novel Retractor With a Caspar Retractor in Anterior Cervical Surgery

Neurosurgery 69[ONS Suppl 2]:ons156–ons160, 2011 DOI: 10.1227/NEU.0b013e318219565f

Retraction injury might explain the soft tissue complications seen after anterior cervical surgery. A novel retractor system (Seex retractor system [SRS]) that uses a principle of bone fixation with rotation has been shown to reduce retraction pressure in a cadaveric model of anterior cervical decompression and fusion.

OBJECTIVE: To compare the conventional Cloward-style retractor (CRS) with the SRS in a prospective randomized clinical trial.

METHODS: After ethics and study registration (ACTRN 12608000430336), eligible patients were randomized to either the CRS or SRS before 1- or 2-level anterior cervical decompression and fusion. The pressure beneath the medial retractor blade was recorded with a thin pressure transducer strip. Postoperative sore throat, dysphagia, and dysphonia were assessed after 1, 7, and 28 days.

RESULTS: Twenty-six patients were randomized. There were no serious complications. Complication rates were low with a trend favoring SRS that was not statistically different. Average retraction pressure with SRS was 1.9 mm Hg and with CRS was 5.6 mm Hg (P , .001 on F test; P = .002 on 2-tailed t test). Mean average peak retraction pressure with the SRS was 3.4 mm Hg and with the CRS was 20 mmHg (P , .001 on F test; P = .005 on 2-tailed t test).

CONCLUSION: The new retractor is safe, and statistically similar complication rates were observed with the 2 systems. The SRS generated significantly less retraction pressure compared with the CRS. This difference can be explained by the different principles governing the function of these retractors. Bone fixation gives stability and rotation reduces tissue pressure, both desirable in a retractor.