Timing of intraventricular infusion test for diagnosing idiopathic normal pressure hydrocephalus

Acta Neurochirurgica (2020) 162: 1011–1017

Infusion tests, which measure resistance to outflow (Rout), are used in selecting patients suspected for idiopathic normal pressure hydrocephalus (iNPH) for shunt surgery. Infusion tests can be performed through an external ventricular drain (EVD). A 24-hour time gap from EVD insertion to an infusion test is a routine practice at our department due to concerns that the surgical procedure might influence the test results in the immediate postoperative period. The objective of the study was to investigate if timing of an intraventricular infusion test influences the results of the test in patients suspected for iNPH.

Methods Ten patients scheduled for an intraventricular infusion test were included. Measurements of baseline intracranial pressure (ICP) and plateau ICP were obtained during constant rate intraventricular infusion test performed at two time points (1 and 24 h after EVD insertion) and Rout was calculated from these measures and compared within patients.

Results Eight patients completed both infusion tests. In one of the 18 infusion tests performed, it was not possible to define an ICP plateau and this infusion test was excluded, leaving 7 paired infusion tests.Median Rout was 12.9 mmHg/ml/min (range 7.0–22.0) 1 h after EVD insertion and 11.3 mmHg/ml/min (range 7.8–18.1) after 24 h. Overall, there were no statistically significant differences in Rout (P = 0.83), baseline ICP (P = 0.70), or plateau ICP (P = 0.81) between the recordings performed 1 h and 24 h after EVD insertion. For two of the seven patients with paired infusion tests, there was poor agreement between Rout values at 1 and 24 h.

Conclusion Overall, Rout estimates do not change significantly between 1 and 24 h after EVD insertion.We therefore propose that infusion tests can be performed shortly after surgery to reduce the period of indwelling EVD and duration of hospitalization.

Does aqueductal stenosis influence the lumbar infusion test in normal-pressure hydrocephalus?

Acta Neurochir (2016) 158:2305–2310

Late-onset idiopathic aqueductal stenosis may present with clinical features indistinct from idiopathic normal-pressure hydrocephalus (NPH). Moreover, aqueductal stenosis (AS) is not always detected by conventional magnetic resonance imaging (MRI). The aim of this study was to compare the hydrodynamic pattern among NPH patients according to the patency of the aqueduct.

Methods Fifty-six consecutive lumbar infusion tests were performed in patients with NPH syndrome. Precipitating causes of hydrocephalus were excluded, and aqueductal patency was examined through high-resolution, T2-weighted 3D MRI. Patients were classified into two groups: non-patent aqueduct and patent aqueduct. Mean values of pressure and pulse amplitude were obtained from basal and plateau stages of infusion studies.

Results Twelve of 56 patients with NPH-like symptoms presented with morphological AS (21.4 %). Patent aqueduct and non-patent aqueduct groups had similar values of mean opening lumbar pressure (8.2 vs. 8.1 mmHg), and mean opening pulse amplitude (3.1 vs. 2.9 mmHg). Mean pressure in the plateau stage (28.6 vs. 23.2 mmHg), and mean pulse amplitude in the plateau stage (12.5 vs. 10.6 mmHg) were higher in the patent aqueduct group. These differences were not statistically significant. Only Rout was significantly higher in the patent aqueduct group (13.6 vs. 10.1 mmHg/ml/min). One-third of NPH patients with AS presented Rout >12 mmHg/ ml/min.

Conclusions No differences in mean pressure or pulse amplitude during basal and plateau epochs of the lumbar infusion test in NPH patients were detected, regardless of aqueductal patency. However, Rout was significantly higher in patients with patent aqueduct.

Selection of patients with idiopathic normal-pressure hydrocephalus for shunt placement: a single-institution experience

J Neurosurg 113:64–73, 2010. DOI: 10.3171/2010.1.JNS091296

The ability to predict outcome after shunt placement in patients with idiopathic normal-pressure hydrocephalus (NPH) represents a challenge. To date, no single diagnostic tool or combination of tools has proved capable of reliably predicting whether the condition of a patient with suspected NPH will improve after a shunting procedure. In this paper, the authors report their experience with 120 patients with the goal of identifying CSF hydrodynamics criteria capable of selecting patients with idiopathic NPH. Specifically, they focused on the comparison between CSF-outflow resistance (R-out) and intracranial elastance (IE).

Methods. Between January 1977 and December 2005, 120 patients in whom idiopathic NPH had been diagnosed (on the basis of clinical findings and imaging) underwent CSF hydrodynamics evaluation based on an intraventricular infusion test. Ninety-six patients underwent CSF shunt placement: 32 between 1977 and 1989 (Group I) on the basis of purely clinical and radiological criteria; 44 between 1990 and 2002 (Group II) on the basis of the same criteria as Group I and because they had an IE slope > 0.25; and 20 between 2003 and 2005 (Group III) on the basis of the same criteria as Group II but with an IE slope ≥ 0.30. Outcomes were evaluated by means of both Stein-Langfitt and Larsson scores. Patients’ conditions were considered improved when there was a stable decrease (at 6- and 12-month follow-up) of at least 1 point in the Stein-Langfitt score and 2 points in the Larsson score.

Results. Group I: while no statistically significant difference in mean R-out value between improved and unimproved cases was observed, a clear-cut IE slope value of 0.25 differentiated very sharply between unimproved and improved cases. Group II: R-out values in the 2 unimproved cases were 20 and 47 mm Hg/ml/min, respectively. The mean IE slope in the improved cases was 0.56 (range 0.30–1.4), while the IE slopes in the 2 unimproved cases were 0.26 and 0.27. Group III: the mean IE slope was 0.51 (range 0.31–0.7). The conditions of all patients improved after shunting. A significant reduction of the Evans ratio was observed in 34 (40.5%) of the 84 improved cases and in none of the unimproved cases.

Conclusions. Our strategy based on the analysis of CSF pulse pressure parameters seems to have a great accuracy in predicting surgical outcome in clinical practice.