Timing of intraventricular infusion test for diagnosing idiopathic normal pressure hydrocephalus

Acta Neurochirurgica (2020) 162: 1011–1017

Infusion tests, which measure resistance to outflow (Rout), are used in selecting patients suspected for idiopathic normal pressure hydrocephalus (iNPH) for shunt surgery. Infusion tests can be performed through an external ventricular drain (EVD). A 24-hour time gap from EVD insertion to an infusion test is a routine practice at our department due to concerns that the surgical procedure might influence the test results in the immediate postoperative period. The objective of the study was to investigate if timing of an intraventricular infusion test influences the results of the test in patients suspected for iNPH.

Methods Ten patients scheduled for an intraventricular infusion test were included. Measurements of baseline intracranial pressure (ICP) and plateau ICP were obtained during constant rate intraventricular infusion test performed at two time points (1 and 24 h after EVD insertion) and Rout was calculated from these measures and compared within patients.

Results Eight patients completed both infusion tests. In one of the 18 infusion tests performed, it was not possible to define an ICP plateau and this infusion test was excluded, leaving 7 paired infusion tests.Median Rout was 12.9 mmHg/ml/min (range 7.0–22.0) 1 h after EVD insertion and 11.3 mmHg/ml/min (range 7.8–18.1) after 24 h. Overall, there were no statistically significant differences in Rout (P = 0.83), baseline ICP (P = 0.70), or plateau ICP (P = 0.81) between the recordings performed 1 h and 24 h after EVD insertion. For two of the seven patients with paired infusion tests, there was poor agreement between Rout values at 1 and 24 h.

Conclusion Overall, Rout estimates do not change significantly between 1 and 24 h after EVD insertion.We therefore propose that infusion tests can be performed shortly after surgery to reduce the period of indwelling EVD and duration of hospitalization.

Evaluation of a novel noninvasive ICP monitoring device in patients undergoing invasive ICP monitoring: preliminary results

J Neurosurg 128:1653–1660, 2018

There is no established method of noninvasive intracranial pressure (NI-ICP) monitoring that can serve as an alternative to the gold standards of invasive monitoring with external ventricular drainage or intraparenchymal monitoring. In this study a new method of NI-ICP monitoring performed using algorithms to determine ICP based on acoustic properties of the brain was applied in patients undergoing invasive ICP (I-ICP) monitoring, and the results were analyzed.

METHODS In patients with traumatic brain injury and subarachnoid hemorrhage who were undergoing treatment in a neurocritical intensive care unit, the authors recorded ICP using the gold standard method of invasive external ventricular drainage or intraparenchymal monitoring. In addition, the authors simultaneously measured the ICP noninvasively with a device (the HS-1000) that uses advanced signal analysis algorithms for acoustic signals propagating through the cranium. To assess the accuracy of the NI-ICP method, data obtained using both I-ICP and NI-ICP monitoring methods were analyzed with MATLAB to determine the statistical significance of the differences between the ICP measurements obtained using NI-ICP and I-ICP monitoring.

RESULTS Data were collected in 14 patients, yielding 2543 data points of continuous parallel ICP values in recordings obtained from I-ICP and NI-ICP. Each of the 2 methods yielded the same number of data points. For measurements at the ≥ 17–mm Hg cutoff, which was arbitrarily chosen for this preliminary analysis, the sensitivity and specificity for the NI-ICP monitoring were found to be 0.7541 and 0.8887, respectively. Linear regression analysis indicated that there was a strong positive relationship between the measurements. Differential pressure between NI-ICP and I-ICP was within ± 3 mm Hg in 63% of data-paired readings and within ± 5 mm Hg in 85% of data-paired readings. The receiver operating characteristic–area under the curve analysis revealed that the area under the curve was 0.895, corresponding to the overall performance of NI-ICP monitoring in comparison with I-ICP monitoring.

CONCLUSIONS This study provides the first clinical data on the accuracy of the HS-1000 NI-ICP monitor, which uses advanced signal analysis algorithms to evaluate properties of acoustic signals traveling through the brain in patients undergoing I-ICP monitoring. The findings of this study highlight the capability of this NI-ICP device to accurately measure ICP noninvasively. Further studies should focus on clinical validation for elevated ICP values.

Elective ICP monitoring: how long is long enough?

Acta Neurochir (2017) 159:485–490

Intracranial pressure monitoring is commonly undertaken to assess and manage acute patients following head injury. However, ICP monitoring can also be a useful diagnostic tool in the management of CSF dynamics in elective patients. To date, there is little published research to suggest how long these elective patients require ICP monitoring in order to gain an accurate picture of a patient’s ICP dynamics. At the author’s institution, a minimum of 48-h data collection is currently undertaken in patients with a suspected ICP abnormality.

Methods A retrospective audit was undertaken comparing overall median ICP and overall median pulse amplitude data at three time points, 24 h, 48 h and total time analysed (if longer than 48 h). Paired T-test was used to assess if there were statistically significant differences between 24-h versus 48-h monitoring and total duration of monitoring. All patients admitted over a 6-month period for ICPM who met the inclusion/exclusion criteria were included.

Results Eighteen patients met the criteria. Median age was 45.8 years, range 22–83 years, 12 female and 6 male. No complications were experienced as a result of ICPM. Diagnosis included NPH, IIH, suspected shunt malfunction and Chiari malformation. The results demonstrated that there is no statistical difference between 24 h and 48 h or longer for both overall median ICP and pulse amplitude.

Conclusion The results of this study demonstrate that ICP monitoring of elective adult patients using a Spiegelberg intraparenchymal bolt for 24 h gives an accurate picture of a patient’s ICP dynamics compared with longer periods of monitoring.

Is Intracranial Pressure Monitoring of Patients With Diffuse Traumatic Brain Injury Valuable?

ICP

Neurosurgery 78:361–369, 2016

Although intracranial pressure (ICP) monitoring of patients with severe traumatic brain injury (TBI) is recommended by the Brain Trauma Foundation, any benefits remain controversial.

OBJECTIVE: To evaluate the effects of ICP monitoring on the mortality of and functional outcomes in patients with severe diffuse TBI.

METHODS: Data were collected on patients with severe diffuse TBI (Glasgow Coma Scale [GCS] score on admission ,9 and Marshall Class II-IV) treated from January 2012 to December 2013 in 24 hospitals (17 level I trauma centers and 7 level II trauma centers) in 9 Chinese provinces. We evaluated the impact of ICP monitoring on 6-month mortality and favorable outcome using propensity score–matched analysis after controlling for independent predictors of these outcomes.

RESULTS: ICP monitors were inserted into 287 patients (59.5%). After propensity score matching, ICP monitoring significantly decreased 6-month mortality. ICP monitoring also had a greater impact on the most severely injured patients on the basis of head computed tomography data (Marshall computed tomography classification IV) and on patients with the lowest level of consciousness (GCS scores 3-5). After propensity score matching, monitoring remained nonassociated with a 6-month favorable outcome for the overall sample. However, monitoring had a significant impact on the 6-month favorable outcomes of patients with the lowest level of consciousness (GCS scores 3-5).

CONCLUSION: ICP monitor placement was associated with a significant decrease in 6-month mortality after adjustment for the baseline risk profile and the monitoring propensity of patients with diffuse severe TBI, especially those with GCS scores of 3 to 5 or of Marshall computed tomography classification IV.

New Telemetric Intracranial Pressure-Monitoring System

Neurosurgery 70[ONS Suppl 1]:ons44–ons49, 2012 DOI: 10.1227/NEU.0b013e31822dda12 

The knowledge of intracranial pressure (ICP) is the basis of an appropriate neurosurgical treatment. Because clinical, fundoscopic, or radiological data alone are often elusive, a pre- or postoperative long-term monitoring of the ICP itself is desirable.

OBJECTIVE: We describe the first clinical experiences with a new telemetric ICPmonitoring device.

METHODS: The transducer of this telemetric intraparenchymal pressure probe is placed under the galea over the calvaria. ICP can be monitored via a special telemetric reader, placed over the intact skin, and the ICP values are stored in a small portable computer. The system does not require an intensive care environment and can be used in any ward or even at home. The system was successfully applied in 10 patients (age, 3- 56 years) in whom raised ICP due to hydrocephalus, shunt dysfunction, endoscopic third ventriculostomy failure, craniostenosis, or pseudotumor cerebri was suspected.

RESULTS: Continuous telemetric monitoring of ICP was performed for 2 to 24 weeks. In 7 patients, increased ICP values could be excluded, and further surgical maneuvers were avoided. In 3 patients, repeated plateaus or continuously raised ICP indicated surgery resulting in a normalization of ICP.

CONCLUSION: This new telemetric system was safe and effective for ICP measurement over a long period, including home monitoring. For the patients, it was easy to handle, and reliable data could be recorded over many weeks. Based on this preliminary experience, the authors consider the new system extremely advantageous in surgical decision making in particularly difficult cases of suspected abnormalities of ICP.

Investigating shunt function using continuous intracranial pressure monitoring in adults: single center experience

J Neurosurg 113:1326–1330, 2010. (DOI: 10.3171/2010.8.JNS1067)

Managing symptomatic ventriculoperitoneal shunts with no clear evidence of shunt malfunction either clinically or radiologically can be a difficult task. The aim of this study was to assess intracranial pressure (ICP) monitoring as a method of investigating shunt function.

Methods. The authors performed a retrospective analysis of 38 continuous ICP monitoring procedures done in patients with ventriculoperitoneal shunts and suspected shunt malfunction.

Results. Thirty-eight procedures were performed in 31 patients between January 2005 and October 2008. Sixteen recordings were normal, 6 revealed overdrainage or low pressure, 11 indicated underdrainage or high pressure, and 5 showed variable shunt function. Based on the findings after 20 procedures (53%), patients were treated conservatively: 4 by readjusting the valve setting and 16 by referral to the headache neurologist for medical treatment. Forty-five percent of the conservatively treated patients improved. Surgical exploration was undertaken following 18 procedures (47%); 72% of the surgically treated patients improved.

Conclusions. Continuous ICP monitoring using an intraparenchymal probe is a safe and effective method of investigating adult hydrocephalus.

Monitoring intracranial pressure in patients with malignant middle cerebral artery infarction: is it useful?

J Neurosurg 112:648–657, 2010. DOI: 10.3171/2009.7.JNS081677

Intracranial pressure (ICP) monitoring is increasingly used in the treatment of patients with malignant middle cerebral artery (MCA) infarction. However, neurological deterioration may exist independent from intracranial hypertension. This study aimed to present the findings of continuous ICP monitoring in a cohort of patients with malignant MCA infarction and to correlate these findings with clinical and radiological features.

Methods. The authors studied a prospective cohort of 25 patients with malignant MCA infarction consecutively admitted to the neurotrauma intensive care unit of the Vall d’Hebron University Hospital between March 2002 and September 2006. The patients were treated using a combined protocol of initial moderate hypothermia and hemi-craniectomy. The latter was performed when patients showed a midline shift (MLS) ≥ 5 mm or ICP > 20 mm Hg. Six patients had an MLS ≥ 5 mm on the first CT scan and underwent surgery without prior ICP monitoring. This study focuses on the subgroup of 19 patients who underwent intraparenchymatous ICP monitoring before surgery.

Results. Intracranial pressure readings were evaluated and correlated with pupillary abnormalities, MLS, and ischemic tissue volume. In 12 of the 19 patients, ICP values were always ≤ 20 mm Hg, despite a mean (± SD) MLS of 6.7 ± 2 mm and a mean ischemic tissue volume of 241.3 ± 83 cm3. In 2 patients with anisocoria, ICP values were also normal.

Conclusions. In patients with a malignant MCA infarction, pupillary abnormalities and severe brainstem compression may be present despite normal ICP values. Therefore, continuous ICP monitoring cannot substitute for close clinical and radiological follow-up in the management of these patients.

Diagnostic Intracranial Pressure Monitoring and Surgical Management in Idiopathic Normal Pressure Hydrocephalus: A 6-Year Review of 214 Patients

Neurosurgery 66:80-91, 2010 DOI: 10.1227/01.NEU.0000363408.69856.B8

OBJECTIVE: To review our experience of managing idiopathic normal pressure hydrocephalus (iNPH) during the 6-year period from 2002 to 2007, when intracranial pressure (ICP) monitoring was part of the diagnostic workup.

METHODS: The review includes all iNPH patients undergoing diagnostic ICP monitoring during the years 2002 to 2007. Clinical grading was done prospectively using a normal pressure hydrocephalus (NPH) grading scale (scores from 3 to 15). The selection of patients for surgery was based on clinical symptoms, enlarged cerebral ventricles, and findings on ICP monitoring. The median follow-up time was 2 years (range, 0.3-6 years). Both static ICP and pulsatile ICP were analyzed.

RESULTS: A total of 214 patients underwent the diagnostic workup, of whom 131 went on to surgery. Although 1 patient died shortly after treatment, 103 of the 130 patients (79%) improved clinically. This improvement lasted throughout the observation period. The static ICP observed during ICP monitoring was a poor predictor of the response to surgery. In contrast, among 109 of 130 patients with increased ICP pulsatility (ie, ICP wave amplitude >4 mm Hg on average and >5 mm Hg in >10% of recording time), 101 (93%) were responders (ie, increase in the NPH score of >2). Correspondingly, only 2 of 21 (10%) without increased ICP pulsatility were responders. Superficial wound infection was the only complication of ICP monitoring and occurred in 4 (2%) patients.

CONCLUSION: Surgical results in iNPH were good with almost 80% of patients improving after treatment. The data indicate that improvement after surgery can be anticipated in 9 of 10 iNPH patients with abnormal ICP pulsatility, but in only 1 of 10 with normal ICP pulsatility. Diagnostic ICP monitoring had a low complication rate