Flow-Diverting Stents for Intracranial Bifurcation Aneurysm Treatment

Flowdiverter

Neurosurgery 75:623–631, 2014

Although initially considered safe when covering bifurcation sites, flow-diverting stents may provoke thrombosis of side branches that are covered during aneurysm treatment.

OBJECTIVE: To understand the occurrence and clinical expression of side-branch remodeling in distal intracranial arterial sites after flow diverter deployment by means of correlation of imaging and clinical data.

METHODS: We analyzed our prospectively collected data on a series of patients treated with flow diverters for intracranial aneurysms at bifurcation sites. From February 2011 to May 2013, 32 patients with 37 aneurysms (anterior communicating artery, 9 [24.3%]; anterior cerebral artery, 5 [13.5%]; middle cerebral artery, 19 (51.4%); terminal internal carotid artery, 4 [10.8%]) were treated. We divided aneurysms into 2 groups based on the side branches covered by the stent during treatment. Group A consisted of cases with side branches that supplied brain territories also receiving a direct collateral supply. Group B consisted of cases in which side branches supplied territories without direct collateral supply. The 2 groups were compared statistically.

RESULTS: Total exclusion occurred in 97.3% of aneurysms at follow-up. Initial modified Rankin Scale (mRS) score was 0 to 1 for 29 patients (90.6%) and 2 for 3 patients (9.4%). New permanent neurological deficit was reported in 3 patients (9.4%). At the 6-month follow-up, the mRS score was 0 to 1 for 31 patients (96.8%) and 3 for 1 patient (3.2%). Although 78.5% of side branches in group A underwent narrowing or occlusion after 6 months, no new stroke was found on magnetic resonance imaging.

CONCLUSION: Symptomatic modifications of side branches after flow diverter treatment depend on the extent and type of collateral supply.

Single-center experience with the Neuroform stent for endovascular treatment of wide-necked intracranial aneurysms

Surgical Neurology 72 (2009) 612–619. DOI:10.1016/j.surneu.2009.03.038

Background: Stent-assisted coiling is an accepted endovascular treatment (EVT) for wide-necked intracranial aneurysms. The Neuroform stent (Target Therapeutics, Fremont, Calif) is a flexible nitinol self-expandable stent that was designed to potentially overcome the limitations of balloon expandable coronary stents in the intracranial circulation. The aim of this study was to reenforce the use of this stent for EVT of wide-necked cerebral aneurysms.

Methods: Between March 2005 and March 2008, 24 patients harboring wide-necked cerebral aneurysms were treated with stent reconstruction of the aneurysm neck. Inclusion criteria restricted the group to adult patients with wide-necked intracranial aneurysms (ruptured and unruptured lesions). Immediate postprocedure angiography studies were performed to determine successful coil occlusion of the aneurysm as well as patency of the parent vessel. We assessed the clinical history, aneurysm dimensions, and technical detail of the procedures, including any difficulties with stent placement and deployment, degree of aneurysm occlusion, and complications. Clinical outcome was assessed with the Glasgow Outcome Scale (GOS).

Results: The stent was easily navigated and precisely positioned in 24 of 26 cases. However, technical difficulties occurred in 9 patients, including difficulties in crossing the stents interstice in 6 cases, inadvertent stent delivery (n = 1), and incapacity of stent delivery (n = 1) and incapacity of crossing the neck (n = 1). These latter 2 cases were classified as failures of the stent-assisted technique. A single procedural complication occurred, involving transient nonocclusive intrastent thrombus formation, which was treated uneventfully with abciximab. Seventeen patients experienced excellent clinical outcomes (GOS 5), with good outcomes (GOS 4) in 5 patients and a poor outcome (GOS 3) in 2 patients. There were no treatment-related deaths or neurologic complications (mean clinical follow-up, 12 months). Angiographic results consisted of 17 complete occlusions, 4 neck remnants, and 3 incomplete occlusions.

Conclusions: The Neuroform stent is very useful for EVT of wide-necked intracranial aneurysms because it is easy to navigate and to deploy accurately. In most cases, the stent can be deployed precisely, even in very tortuous carotid siphons. Although in some cases delivery and deployment was challenging, clinically significant complications were not observed.