A basic model for training of microscopic and endoscopic transsphenoidal pituitary surgery: the Egghead

A basic model for training of microscopic and endoscopic transsphenoidal pituitary surgery- the Egghead

Acta Neurochir (2015) 157:1771–1777

Transsphenoidal endoscopic surgery has gained popularity in the last 2 decades and is becoming a standard technique for resection of pituitary adenomas. In contrast to their ENT colleagues, neurosurgical residents have practically no endoscopic experience when they reach the training stage for transsphenoidal procedures.

We have developed an affordable method for repetitive training in endoscopic (and microscopic) work in a narrow channel, allowing training of the basic movements needed for resection of pituitary adenoma.

Methods In collaboration with colleagues in the ENT Department, Cantonal Hospital St. Gall, and the Technical University of Zurich, a three-dimensional model of the nasal cavity was developed and patented. The Egghead model consists of a 3D synthetic reconstruction of the head nasal cavity and sphenoid sinus. A boiled egg represents the sella. For validation, 17 neurosurgical residents from the Department of Neurosurgery, University Hospital of Basel, and Department of Neurosurgery, Cantonal Hospital of St. Gall, St. Gall, Switzerland, and two experts performed a standardized procedure mimicking a transsphenoidal pituitary procedure by dissecting a corridor to the egg yolk and resecting it, respecting the surrounding egg white. This procedure was performed under both microscopic and video-endoscopic visualization. A score for the precision and speed of the surgical performance was developed and used.

Results The model allows repetitive training of the resection of the egg yolk under sparing of the egg white after careful opening of the shell. The validation data showed a steeper learning curve using the endoscopic technique than performing the same task using the microscope. After three repetitions, the quality of resection was better with the endoscopic technique.

Conclusions Our model, the Egghead, is affordable, offers tactile feedback and allows infinite repetitions in basic training for pituitary surgery. It can be used for training of advanced neurosurgical residents, who thus far have very few possibilities of acquiring endoscopic experience.

Integration of Indocyanine Green Videoangiography With Operative Microscope: Augmented Reality for Interactive Assessment of Vascular Structures and Blood Flow

Integration of Indocyanine Green Videoangiography With Operative Microscope

Operative Neurosurgery 11:252–258, 2015

Preservation of adequate blood flow and exclusion of flow from lesions are key concepts of vascular neurosurgery. Indocyanine green (ICG) fluorescence videoangiography is now widely used for the intraoperative assessment of vessel patency.

OBJECTIVE: Here, we present a proof-of-concept investigation of fluorescence angiography with augmented microscopy enhancement: real-time overlay of fluorescence videoangiography within the white light field of view of conventional operative microscopy.

METHODS: The femoral artery was exposed in 7 anesthetized rats. The dissection microscope was augmented to integrate real-time electronically processed near-infrared filtered images with conventional white light images seen through the standard oculars. This was accomplished by using an integrated organic light-emitting diode display to yield superimposition of white light and processed near-infrared images. ICG solution was injected into the jugular vein, and fluorescent femoral artery flow was observed.

RESULTS: Fluorescence angiography with augmented microscopy enhancement was able to detect ICG fluorescence in a small artery of interest. Fluorescence appeared as a bright-green signal in the ocular overlaid with the anatomic image and limited to the anatomic borders of the femoral artery and its branches. Surrounding anatomic structures were clearly visualized. Observation of ICG within the vessel lumens permitted visualization of the blood flow. Recorded video loops could be reviewed in an offline mode for more detailed assessment of the vasculature.

CONCLUSION: The overlay of fluorescence videoangiography within the field of view of the white light operative microscope allows real-time assessment of the blood flow within vessels during simultaneous surgical manipulation. This technique could improve intraoperative decision making during complex neurovascular procedures.