“Live cadavers” for training in the management of intraoperative aneurysmal rupture

“Live cadavers” for training in the management of intraoperative aneurysmal rupture

J Neurosurg 123:1339–1346, 2015

Intraoperative rupture occurs in approximately 9.2% of all cranial aneurysm surgeries. This event is not merely a surgical complication, it is also a real surgical crisis that requires swift and decisive action. Neurosurgical residents may have little exposure to this event, but they may face it in their practice. Laboratory training would be invaluable for developing competency in addressing this crisis. In this study, the authors present the “live cadaver” model, which allows repetitive training under lifelike conditions for residents and other trainees to practice managing this crisis.

Methods The authors have used the live cadaver model in 13 training courses from 2009 to 2014 to train residents and neurosurgeons in the management of intraoperative aneurysmal rupture. Twenty-three cadaveric head specimens harboring 57 artificial and 2 real aneurysms were used in these courses. Specimens were specially prepared for this technique and connected to a pump that sent artificial blood into the vessels. This setting created a lifelike situation in the cadaver that simulates live surgery in terms of bleeding, pulsation, and softness of tissue.

Results A total of 203 neurosurgical residents and 89 neurosurgeons and faculty members have practiced and experienced the live cadaver model. Clipping of the aneurysm and management of an intraoperative rupture was first demonstrated by an instructor. Then, trainees worked for 20- to 30-minute sessions each, during which they practiced clipping and reconstruction techniques and managed intraoperative ruptures. Ninety-one of the participants (27 faculty members and 64 participants) completed a questionnaire to rate their personal experience with the model. Most either agreed or strongly agreed that the model was a valid simulation of the conditions of live surgery on cerebral aneurysms and represents a realistic simulation of aneurysmal clipping and intraoperative rupture. Actual performance improvement with this model will require detailed measurement for validating its effectiveness. The model lends itself to evaluation using precise performance measurements.

Conclusions The live cadaver model presents a useful simulation of the conditions of live surgery for clipping cerebral aneurysms and managing intraoperative rupture. This model provides a means of practice and promotes team management of intraoperative cerebrovascular critical events. Precise metric measurement for evaluation of training performance improvement can be applied.

Three-dimensional simulation for aneurysm surgery

Neurosurgery 65:719–726, 2009 DOI: 10.1227/01.NEU.0000354350.88899.07

OBJECTIVE: With improvements in endovascular techniques, fewer aneurysms are treated by surgical clipping, and those aneurysms targeted for open surgery are often complex and difficult to treat. We devised a hollow, 3-dimensional (3D) model of individual cerebral aneurysms for preoperative simulation and surgical training. The methods and initial experience with this model system are presented.

METHODS:The 3D hollow aneurysm models of 3 retrospective and 8 prospective cases were made with a prototyping technique according to data from 3D computed tomographic angiograms of each patient. Commercially available titanium clips used in our routine surgery were applied, and the internal lumen was observed with an endoscope to confirm the patency of parent vessels. The actual surgery was performed later.

RESULTS: In the 8 prospective cases, the clips were applied during surgery in the same direction and configuration as in the preoperative simulation. Fine adjustments were necessary in each case, and 2 patients needed additional clips to occlude the atherosclerotic aneurysmal wall. With these 3D models, it was easy for neurosurgical trainees to grasp the vascular configuration and the concept of neck occlusion. Practicing surgery with these models also improved their handling of the instruments used during

aneurysm surgery, such as clips and appliers.