Thalamic and Subthalamic Deep Brain Stimulation for Essential Tremor: Where Is the Optimal Target?

Neurosurgery 70:840–846, 2012 DOI: 10.1227/NEU.0b013e318236a809

The ventrolateral thalamus (ventral intermediate nucleus [Vim]) is the traditional target for neurosurgical treatment of essential tremor. The target, however, has varied substantially among different neurosurgeons.

OBJECTIVE: To evaluate the effect of deep brain stimulation in the thalamus and posterior subthalamic area (PSA) in relation to electrode location.

METHODS: Thirty-six (17 Vim/19 PSA) patients with 44 deep brain stimulation electrodes were included in this retrospective study. The effect of stimulation was evaluated with standardized settings for each contact using items from the Essential Tremor Rating Scale.

RESULTS: When each contact was evaluated in terms of the treated hand with standardized stimulation, the electrode contact providing the best effect in the individual patient was located in the zona incerta or radiation prelemniscalis in 54% and the Vim in 12%. Forty contacts provided a tremor reduction of . 90%. Of these, 43% were located in the PSA and 18% in the Vim according to the Schaltenbrand atlas. Of these 40 contacts, 37 were found in the PSA group.

CONCLUSION: More contacts yielding an optimal effect were found in the PSA group than in the Vim. Many patients operated on in the Vim got the best effect from a contact located in the PSA. This might suggest that the PSA is a more efficient target than the Vim.

A role of diffusion tensor imaging in movement disorder surgery

Acta Neurochir DOI 10.1007/s00701-010-0742-2

The safe and reversible nature of deep brain stimulation (DBS) has allowed movement disorder neurosurgery to become commonplace throughout the world. Fundamental understanding of individual patient’s anatomy is critical for optimizing the effects and side effects of DBS surgery. Three patients undergoing stereotactic surgery for movement disorders, at the institution’s intraoperative magnetic resonance imaging operating suite, were studied with fiber tractography. Stereotactic targets and fiber tractography were determined on preoperative magnetic resonance imagings using the Schaltenbrand–Wahren atlas for definition in the BrainLab iPlan software (BrainLAB Inc., Feldkirchen, Germany). Subthalamic nucleus, globus pallidus interna, and ventral intermediate nucleus targets were studied. Diffusion tensor imaging parameters used ranged from 2 to 8 mm for volume of interest in the x/y/z planes, fiber length was kept constant at 30 mm, and fractional anisotropy threshold varied from 0.20 to 0.45. Diffusion tensor imaging tractography allowed reliable and reproducible visualization and correlation between frontal eye field, premotor, primary motor, and primary sensory cortices via corticospinal tracts and corticopontocerebellar tracts. There is an apparent increase in the number of cortical regions targeted by the fiber tracts as the region of interest is enlarged. This represents a possible mechanism of the increased effects and side effects observed with higher stimulation voltages. Currently available diffusion tensor imaging techniques allow potential methods to characterize the effects and side effects of DBS. This technology has the potential of being a powerful tool to optimize DBS neurosurgery