Acta Neurochirurgica (2023) 165:1227–1231
Anterior communicating artery aneurysms are most prone to rupture. Surgically, they are conventionally being managed by a pterional approach. Some neurosurgeons prefer a supraorbital keyhole approach in select cases. Fully endoscopic clipping of such aneurysms is seldom described.
Method We clipped an antero-inferiorly directed anterior communicating artery aneurysm endoscopically via a supraorbital keyhole approach. The intraoperative aneurysmal rupture was also managed endoscopically. The patient made an excellent postoperative recovery without any neurological deficits.
Conclusion Select cases of anterior communicating artery aneurysms can be clipped endoscopically using standard instruments and adhering to the basic principles of aneurysm clipping.