Accurate placement of thoracolumbar pedicle screws using a handheld iOS-based navigation device

The Spine Journal 24 (2024) 1671−1677

Accurate pedicle screw placement is a challenge with reported misplacement rates of 10% and higher. A handheld navigation device (HND) may provide accuracy equal to CT-based navigation (CT-Nav) but without the cost and complexity.

OBJECTIVE: To study the accuracy of a handheld navigation device for pedicle screw placement. STUDY DESIGN: This prospective cross-sectional study with consistently applied reference standard enrolled 20 patients undergoing 92 pedicle screw placements.

PATIENTS: Patients who underwent pedicle screw placement between May 2022 and September 2022.

OUTCOME MEASURES: Pedicle screw placement accuracy per Gertzbein−Robbins.

METHODS: Once the screw pilot hole was established, the proposed trajectory of the HND was compared with that proposed by CT-Nav. Postoperatively, screw accuracy was graded according to Gertzbein−Robbins by a blinded radiologist based on CT scans. Accuracy was compared between the two systems and published control for fluoroscopy assisted and CT-Nav placement using Bayesian posterior distribution.

RESULTS: The trajectory proposed by the HND and CT-Nav were in agreement in 98.9% (95% Exact CI; 94.09%−99.97%). The HND accuracy was 98.9% with 91 screws rated “A” and 1 rated “C”. Noninferiority to fluoroscopic placement was achieved because the one-sided normalapproximation 95% CI Lower Bound (LB) of 95.3% is greater than the Performance Goal (PG) of 83.4%. Posthoc analysis demonstrated that the probability of superiority of the HND relative to the historical accuracy rate of 91.5% for fluoroscopy assisted procedures is >0.999 and that the HND’s accuracy rate is within 4.5% of CT-Nav of 95.5% is >0.999. No adverse events or intra-operative complications associated with HND were observed. There was 1 (1.1%) intra-operative repositioning and no reoperations for any reason.

CONCLUSIONS: The accuracy rate of the HND was 98.9%, and the proposed trajectory matched with CT-Nav in 98.9% of the time. This is superior to the historical published accuracy rate for fluoroscopy-assisted procedures and equivalent to the historical published accuracy rate for CT-Nav.

Surgical or endovascular management of ruptured intracranial aneurysms: an agreement study

J Neurosurg 131:25–31, 2019

Ruptured intracranial aneurysms (RIAs) can be managed surgically or endovascularly. In this study, the authors aimed to measure the interobserver agreement in selecting the best management option for various patients with an RIA.

METHODS The authors constructed an electronic portfolio of 42 cases of RIA in which an angiographic image along with a brief clinical vignette for each patient were displayed. Undisclosed to the responders was that the RIAs had been categorized as International Subarachnoid Aneurysm Trial (ISAT) (small, anterior-circulation, non–middle cerebral artery location, n = 18) and non-ISAT (n = 22) aneurysms; the non-ISAT group also included 2 basilar apex aneurysms for which a high number of endovascular choices was expected. The portfolio was sent to 132 clinicians who manage pa- tients with RIAs and circulated to members of an American surgical association. Judges were asked to choose between surgical and endovascular management, to indicate their level of confidence in the choice of treatment on a quantitative 0–10 scale, and to determine whether they would include the patient in a randomized trial in which both treatments are compared. Eleven clinicians were asked to respond twice at least 1 month apart. Responses were analyzed using kappa statistics.

RESULTS Eighty-five clinicians (58 cerebrovascular surgeons, 21 interventional neuroradiologists, and 6 interventional neurologists) answered the questionnaire. Overall, endovascular management was chosen more frequently (n = 2136 [59.8%] of 3570 answers). The proportions of decisions to clip were significantly higher for non-ISAT (50.8%) than for ISAT (26.2%) aneurysms (p = 0.0003). Interjudge agreement was only fair (kappa 0.210, 95% CI 0.158–0.276) for all cases and judges, despite high confidence levels (mean score > 8 for all cases). Agreement was no better within sub- groups of clinicians with the same specialty, years of experience, or location of practice or across capability groups (ability to clip or coil, or both). When agreement was defined as > 80% of responders choosing the same option, agreement occurred for only 7 of 40 cases, all of which were ISAT aneurysms, for which coiling was preferred.

CONCLUSIONS Agreement between clinicians regarding the best management option was infrequent but centered around coiling for some ISAT aneurysms. Surgical clipping was chosen more frequently for non-ISAT aneurysms than for ISAT aneurysms. Patients with such an aneurysm might be candidates for inclusion in randomized trials.