Detection of impending perfusion deficits by intraoperative computed tomography (iCT) in aneurysm surgery of the anterior circulation

Acta Neurochirurgica (2021) 163:3501–3514

The aim of our study was to evaluate the additional benefit of intraoperative computed tomography (iCT), intraoperative computed tomography angiography (iCTA), and intraoperative computed tomography perfusion (iCTP) in the intraoperative detection of impending ischemia to established methods (indocyanine green videoangiography (ICGVA), microDoppler, intraoperative neuromonitoring (IONM)) for initiating timely therapeutic measures.

Methods Patients with primary aneurysms of the anterior circulation between October 2016 and December 2019 were included. Data of iCT modalities compared to other techniques (ICGVA, microDoppler, IONM) was recorded with emphasis on resulting operative conclusions leading to inspection of clip position, repositioning, or immediate initiation of conservative treatment strategies. Additional variables analyzed included patient demographics, aneurysm-specific characteristics, and clinical outcome.

Results Of 194 consecutive patients, 93 patients with 100 aneurysms received iCT imaging. While IONM and ICGVA were normal, an altered vessel patency in iCTA was detected in 5 (5.4%) and a mismatch in iCTP in 7 patients (7.5%). Repositioning was considered appropriate in 2 patients (2.2%), where immediate improvement in iCTP could be documented. In a further 5 cases (5.4%), intensified conservative therapy was immediately initiated treating the reduced CBP as clip repositioning was not considered causal. In terms of clinical outcome at last FU, mRS0 was achieved in 85 (91.4%) and mRS1-2 in 7 (7.5%) and remained mRS4 in one patient with SAH (1.1%).

Conclusions Especially iCTP can reveal signs of impending ischemia in selected cases and enable the surgeon to promptly initiate therapeutic measures such as clip repositioning or intraoperative onset of maximum conservative treatment, while established tools might fail to detect those intraoperative pathologic changes.

Intraoperative computed tomography as reliable navigation registration device in 200 cranial procedures

Acta Neurochirurgica (2018) 160:1681–1689

Registration accuracy is a main factor influencing overall navigation accuracy. Standard fiducial- or landmark-based patient registration is user dependent and error-prone. Intraoperative imaging offers the possibility for user-independent patient registration. The aim of this paper is to evaluate our initial experience applying intraoperative computed tomography (CT) for navigation registration in cranial neurosurgery, with a special focus on registration accuracy and effective radiation dose.

Methods A total of 200 patients (141 craniotomy, 19 transsphenoidal, and 40 stereotactic burr hole procedures) were investigated by intraoperative Craneotomía applying a 32-slice movable CTscanner, which was used for automatic navigation registration. Registration accuracy was measured by at least three skin fiducials that were not part of the registration process.

Results Automatic registration resulted in high registration accuracy (mean registration error: 0.93 ± 0.41 mm). Implementation of low-dose scanning protocols did not impede registration accuracy (registration error applying the full dose head protocol: 0.87 ± 0.36mmvs. the low dose sinus protocol 0.72 ± 0.43mm) while a reduction of the effective radiation dose by a factor of 8 could be achieved (mean effective radiation dose head protocol: 2.73 mSv vs. sinus protocol: 0.34 mSv).

Conclusion Intraoperative CT allows highly reliable navigation registration with low radiation exposure.

Intraoperative computed tomography in epilepsy surgery

Intraoperative computed tomography for intracranial electrode implantation surgery in medically refractory epilepsy

J Neurosurg 122:526–531, 2015

Accurate placement of intracranial depth and subdural electrodes is important in evaluating patients with medically refractory epilepsy for possible resection. Confirming electrode locations on postoperative CT scans does not allow for immediate replacement of malpositioned electrodes, and thus revision surgery is required in select cases. Intraoperative CT (iCT) using the Medtronic O-arm device has been performed to detect electrode locations in deep brain stimulation surgery, but its application in epilepsy surgery has not been explored. In the present study, the authors describe their institutional experience in using the O-arm to facilitate accurate placement of intracranial electrodes for epilepsy monitoring.

Methods In this retrospective study, the authors evaluated consecutive patients who had undergone subdural and/or depth electrode implantation for epilepsy monitoring between November 2010 and September 2012. The O-arm device is used to obtain iCT images, which are then merged with the preoperative planning MRI studies and reviewed by the surgical team to confirm final positioning. Minor modifications in patient positioning and operative field preparation are necessary to safely incorporate the O-arm device into routine intracranial electrode implantation surgery. The device does not obstruct surgeon access for bur hole or craniotomy surgery. Depth and subdural electrode locations are easily identified on iCT, which merge with MRI studies without difficulty, allowing the epilepsy surgical team to intraoperatively confirm lead locations.

Results Depth and subdural electrodes were implanted in 10 consecutive patients by using routine surgical techniques together with preoperative stereotactic planning and intraoperative neuronavigation. No wound infections or other surgical complications occurred. In one patient, the hippocampal depth electrode was believed to be in a suboptimal position and was repositioned before final wound closure. Additionally, 4 strip electrodes were replaced due to suboptimal positioning. Postoperative CT scans did not differ from iCT studies in the first 3 patients in the series and thus were not obtained in the final 7 patients. Overall, operative time was extended by approximately 10–15 minutes for O-arm positioning, less than 1 minute for image acquisition, and approximately 10 minutes for image transfer, fusion, and intraoperative analysis (total time 21–26 minutes).

Conclusions The O-arm device can be easily incorporated into routine intracranial electrode implantation surgery in standard-sized operating rooms. The technique provides accurate 3D visualization of depth and subdural electrode contacts, and the intraoperative images can be easily merged with preoperative MRI studies to confirm lead positions before final wound closure. Intraoperative CT obviates the need for routine postoperative CT and has the potential to improve the accuracy of intracranial electroencephalography recordings and may reduce the necessity for revision surgery.

Accuracy of deep brain stimulation electrode placement using intraoperative computed tomography without microelectrode recording

iCT DBS

J Neurosurg 119:301–306, 2013

In this prospective study the authors’ objective was to evaluate the accuracy of deep brain stimulation (DBS) electrode placement using image guidance for direct anatomical targeting with intraoperative CT.

Methods. Preoperative 3-T MR images were merged with intraoperative CT images for planning. Electrode targets were anatomical, based on the MR images. A skull-mounted NexFrame system was used for electrode placement, and all procedures were performed under general anesthesia. After electrode placement, intraoperative CT images were merged with trajectory planning images to calculate accuracy. Accuracy was assessed by both vector error and deviation off the planned trajectory.

Results. Sixty patients (33 with Parkinson disease, 26 with essential tremor, and 1 with dystonia) underwent the procedure. Patient’s mean age was 64 ± 9.5 years. Over an 18-month period, 119 electrodes were placed (all bilateral, except one). Electrode implant locations were the ventral intermediate nucleus (VIM), globus pallidus internus (GPI), and subthalamic nucleus (STN) in 25, 23, and 12 patients, respectively. Target accuracy measurements were as follows: mean vector error 1.59 ± 1.11 mm and mean deviation off trajectory 1.24 ± 0.87 mm. There was no statistically significant difference between the accuracy of left and right brain electrodes. There was a statistically significant (negative) correlation between the distance of the closest approach of the electrode trajectory to the ventricular wall of the lateral ventricle and vector error (r2 = -0.339, p < 0.05, n = 76), and the deviation from the planned trajectory (r2 = -0.325, p < 0.05, n = 77). Furthermore, when the distance from the electrode trajectory and the ventricular wall was < 4 mm, the correlation of the ventricular distance to the deviation from the planned trajectory was stronger (r2 = -0.419, p = 0.05, n = 19). Electrodes placed in the GPI were significantly more accurate than those placed in the VIM (p < 0.05). Only 1 of 119 electrodes required intraoperative replacement due to a vector error > 3 mm. In this series there was one infection and no intraparenchymal hemorrhages.

Conclusions. Placement of DBS electrodes using an intraoperative CT scanner and the NexFrame achieves an accuracy that is at least comparable to other methods.

Accuracy of Image-Guided Pedicle Screw Placement Using Intraoperative Computed Tomography- Based Navigation With Automated Referencing. Part II: Thoracolumbar Spine

Neurosurgery 69:1307–1316, 2011 DOI: 10.1227/NEU.0b013e31822ba190

Image-guided spinal instrumentation may reduce complications in spinal instrumentation.

OBJECTIVE: To assess accuracy, time efficiency, and staff radiation exposure during thoracolumbar screw instrumentation guided by intraoperative computed tomography (iCT)-based neuronavigation (iCT-N).

METHODS: In 55 patients treated for idiopathic and degenerative deformities, 826 screws were inserted in the thoracic (T2–T12; n = 243) and lumbosacral (L1–S1; n = 545) spine, as well as ilium (n = 38) guided by iCT-N. Up to 17 segments were instrumented following a single automated registration sequence with the dynamic reference arc (DRA) uniformly attached to L5. Accuracy of iCT-N was assessed by calculating angular deviations between individual navigated tool trajectories and final implant positions. Final screw positions were also graded according to established classification systems. Clinical and radiological outcome was assessed at 12 to 14 months.

RESULTS: Additional intraoperative fluoroscopy was unnecessary, eliminating staff radiation exposure. Unisegmental K-wire insertion required 4.6 6 2.9 minutes. Of the thoracic pedicle screws 98.4% were assigned grades I to III according to the Heary classification, with 1.6% grade IV placement. In the lumbar spine, 94.4% of screws were completely contained (Gertzbein classification grade 0), 4.6% displayed minor pedicle breaches ,2 mm(grade 1), and 1% of lumbar screws deviated by.2 to,4 mm (grade 2). The accuracy of iCT-N progressively deteriorates with increasing distance from the DRA, but allows safe instrumentation of up to 12 segments.

CONCLUSION: iCT-N using automated referencing allows for safe, highly accurate multilevel instrumentation of the entire thoracolumbosacral spine and ilium, rendering additional intraoperative imaging dispensable. In addition, automated registration is time-efficient and significantly reduces the need for re-registration in multilevel surgery.

Accuracy of Image-Guided Pedicle Screw Placement Using Intraoperative Computed Tomography- Based Navigation With Automated Referencing, Part I: Cervicothoracic Spine

Neurosurgery 69:782–795, 2011 DOI: 10.1227/NEU.0b013e318222ae16

Image-guided spinal instrumentation reduces the incidence of implant misplacement.

OBJECTIVE: To assess the accuracy of intraoperative computed tomography (iCT)-based neuronavigation (iCT-N).

METHODS: In 35 patients (age range, 18-87 years), a total of 248 pedicle screws were placed in the cervical (C1-C7) and upper and midthoracic (T1-T8) spine. An automated iCT registration sequence was used for multisegmental instrumentation, with the reference frame fixed to either a Mayfield head clamp and/or the most distal spinous process within the instrumentation. Pediculation was performed with navigated drill guides or Jamshidi cannulas. The angular deviation between navigated tool trajectory and final implant positions (evaluated on postinstrumentation iCT or postoperative CT scans) was calculated to assess the accuracy of iCT-N. Final screw positions were also graded according to established classification systems. Mean follow-up was 16.7 months.

RESULTS: Clinically significant screw misplacement or iCT-N failure mandating conversion to conventional technique did not occur. A total of 71.4% of patients self-rated their outcome as excellent or good at 12 months; 99.3% of cervical screws were compliant with Neo classification grades 0 and 1 (grade 2, 0.7%), and neurovascular injury did not occur. In addition, 97.8% of thoracic pedicle screws were assigned grades I to III of the Heary classification, with 2.2% grade IV placement. Accuracy of iCT-N progressively deteriorated with increasing distance from the spinal reference clamp but allowed safe instrumentation of up to 10 segments.

CONCLUSION: Image-guided spinal instrumentation using iCT-N with automated referencing allows safe, highly accurate multilevel instrumentation of the cervical and upper and midthoracic spine. In addition, iCT-N significantly reduces the need for reregistration in multilevel surgery.

Intraoperative computed tomography registration and electromagnetic neuronavigation for transsphenoidal pituitary surgery: accuracy and time effectiveness

J Neurosurg 114:329–335, 2011. (DOI: 10.3171/2010.5.JNS091821)

The authors assessed the feasibility, anatomical accuracy, and cost effectiveness of frameless electromagnetic (EM) neuronavigation in conjunction with portable intraoperative CT (iCT) registration for transsphenoidal adenomectomy (TSA).

Methods. A prospective database was established for data obtained in 208 consecutive patients who underwent TSA in which the iCT/EM navigation technique was used. Data were compared with those acquired in a retrospective cohort of 65 consecutive patients in whom fluoroscope-assisted TSA had been performed by the same surgeon. All patients in both groups underwent transnasal removal of pituitary adenomas or neuroepithelial cysts, using identical surgical techniques with an operating microscope. In the iCT/EM technique–treated cases, a portable iCT scan was obtained immediately prior to surgery for registration to the EM navigation system, which did not require rigid head fixation. Preexisting (nonnavigation protocol) MR imaging studies were fused with the iCT scans to enable 3D navigation based on MR imaging data. The accuracy of the navigation system was determined in the first 50 iCT/EM cases by visual concordance of the navigation probe location to 5 preselected bony landmarks. For all patients in both cohorts, total operating room time, incision-to-closure time, and relative costs of imaging and surgical procedures were determined from hospital records.

Results. In every case, iCT registration was successful and preoperative MR images were fused to iCT scans without affecting navigation accuracy. There was 100% concordance between probe tip location and predetermined bony loci in the first 50 cases involving the iCT/EM technique. Total operating room time was significantly less in the iCT/EM cases (mean 108.9 ± 24.3 minutes [208 patients]) compared with the fluoroscopy group (mean 121.1 ± 30.7 minutes [65 patients]; p < 0.001). Similarly, incision-to-closure time was significantly less for the iCT/EM cases (mean 61.3 ± 18.2 minutes) than for the fluoroscopy cases (mean 71.75 ± 19.0 minutes; p < 0.001). Relative overall costs for iCT/EM technique and intraoperative C-arm fluoroscopy were comparable; increased costs for navigation equipment were offset by savings in operating room costs for shorter procedures.

Conclusions. The use of iCT/MR imaging–guided neuronavigation for transsphenoidal surgery is a time-effective, cost-efficient, safe, and technically beneficial technique.

Less Invasive Surgical Correction of Adult Degenerative Scoliosis. Part II: Complications and Clinical Outcome

Neurosurgery 67:1609–1621, 2010 DOI: 10.1227/NEU.0b013e3181f918cf

Surgical correction of adult degenerative scoliosis is a technically demanding procedure with a considerable complication rate. Extensive blood loss has been identified as a significant factor linked to unfavorable outcome.

OBJECTIVE: To report on the complication profile and clinical outcomes obtained with less invasive image-guided surgical correction of degenerative (de novo) scoliosis in a high-risk population.

METHODS: Thirty patients (age, 64-88 years) with progressive postural impairment, back pain, radiculopathy, and neurogenic claudication caused by degenerative scoliosis were treated by less invasive image-guided correction (3-8 segments) by multisegmental transforaminal lumbar interbody fusion and facet fusions. With a mean follow-up of 19.6 months, intraoperative blood loss, curve correction, fusion and complication rates, duration of hospitalization, incidence of hardware-related problems, and clinical outcome parameters were assessed using multivariate analysis.

RESULTS: Satisfactory multiplanar correction was obtained in all patients. Mean intraoperative blood loss was 771.7±231.9 mL, time to full ambulation was 0.8 ± 0.6 days, and length of stay was 8.2 ± 2.9 days. After 12 months, preoperative SF12v2 physical component summary scores (20.2 ± 2.6), visual analog scale scores (7.5 ± 0.8), and Oswestry disability index (57.2 ± 6.9) improved to 34.6 ± 3.9, 2.63 ± 0.6, and 24.8 ± 7.1, respectively. The rate of major and minor complications was 23.4% and 59.9%, respectively. Ninety percent of patients rated treatment success as excellent, good, or fair.

CONCLUSION: Less invasive image-guided correction of degenerative scoliosis in elderly patients with significant comorbidity yields a favorable complication profile. Significant improvements in spinal balance, pain, and functional scores mirrored expedited ambulation and early resumption of daily activities. Less invasive techniques appear suitable to reduce periprocedural morbidity, especially in elderly patients and individuals with significant medical risk factors.