A New Area of Neurosurgery: First Robotic Neurosurgery Clinical Case Series

Operative Neurosurgery 30:929–937, 2026

This clinical report presents the first institutional case series using the da Vinci Xi robotic system applied to neurosurgical procedures, detailing patient selection, operative technique, training, and outcomes for five patients with lesions including clivus chordoma, odontoid metastasis, peroneal neuropathy, and an arachnoid cyst. The series emphasizes procedural feasibility, intraoperative setup, and interdisciplinary collaboration with otolaryngology for transoral and intracranial approaches.

The authors highlight benefits such as enhanced precision, tremor filtration, and minimally invasive access in narrow corridors, while candidly discussing limitations including lack of haptic feedback, high capital costs, training needs, and the current absence of neurosurgery-specific instrument integration; postoperative follow-up showed favorable outcomes without new neurological deficits.

Goal Share early clinical experience adapting the da Vinci Xi surgical robot for neurosurgical procedures, addressing limited current adoption in neurosurgery.

Training Surgeon completed formal robotic training plus simulation, then practiced planned operations on cadavers and calf brains under guidance before clinical use.

Series Five patients underwent robot-assisted neurosurgery (2018–2022) for clivus chordoma (2), odontoid metastatic mass (1), peroneal neuropathy (1), and arachnoid cyst (1).

Technique Cases used a typical 2 robotic arms + 4K camera setup; the surgeon operated from a console with tremor filtration and enhanced instrument dexterity.

Approaches Robotic procedures included transoral tumor resection/odontoidectomy, peroneal nerve decompression, and intracranial arachnoid cyst fenestration (robot used after initial craniotomy steps in the cyst case).

Outcomes No intraoperative or postoperative neurological deficits or complications were observed; all 5 patients had favorable outcomes with 6–24 months follow-up.

Advantages Particular value noted for working in narrow/deep corridors (eg, clivus/odontoid) and for tasks like transoral resection and cyst fenestration, leveraging articulated movement and tremor cancellation.

Limitations/needs Key constraints include lack of tactile feedback, potential device malfunction, nonstandardized training, dedicated staffing needs, and high costs; practical training is emphasized as essential, with further evaluation needed.

A novel robot-assisted method for implanting intracortical sensorimotor devices for brain-computer interface studies

J Neurosurg 142:1280–1288, 2025

A novel robot-assisted method for implanting intracortical microelectrode arrays in brain-computer interface studies was successfully demonstrated in a tetraplegic participant. The technique ensured precise placement, facilitating high-quality signal communication for motor control and sensory feedback, with promising implications for restoring upper-limb function.

• A novel robot-assisted method for implanting intracortical microelectrode arrays in brain-computer interface (BCI) studies is presented, focusing on surgical techniques and challenges.

• The technique was applied in a 31-year-old male with tetraplegia, enabling 2D control of a virtual arm with high success rates and maintaining recording quality over time.

• The robotic neurosurgery technique provides high accuracy and time efficiency, reducing human error and surgeon burden in repetitive procedures.

Preoperative imaging and robotic systems were used for precise planning and execution of array implantations, ensuring minimal cortical damage and high signal quality.

• The study demonstrated that robotic neurosurgery could be successfully translated into BCI device implantation, aiming to restore upper-limb function.

• Future challenges include refining insertion methods, increasing automation, and addressing intraoperative adjustments for microvessels.

• The study was conducted under an investigational device exemption from the US Food and Drug Administration and received institutional review board approval.

Retrospective single-surgeon study of prone versus lateral robotic pedicle screw placement: a CT-based assessment of accuracy

J Neurosurg Spine 39:490–497, 2023

Lateral lumbar interbody fusion including anterior-to-psoas oblique lumbar interbody fusion has conventionally relied on pedicle screw placement (PSP) for construct stabilization. Single-position surgery with lumbar interbody fusion in the lateral decubitus position with concomitant PSP has been associated with increased operative efficiency. What remains unclear is the accuracy of PSP with robotic guidance when compared with the more familiar prone patient positioning. The present study aimed to compare robot-assisted screw placement accuracy between patients with instrumentation placed in the prone and lateral positions.

METHODS The authors identified all consecutive patients treated with interbody fusion and PSP in the prone or lateral position by a single surgeon between January 2019 and October 2022. All pedicle screws placed were analyzed using CT scans to determine appropriate positioning according to the Gertzbein-Robbins classification grading system (grade C or worse was considered as a radiographically significant breach). Multivariate logistic regression models were constructed to identify risk factors for the occurrence of a radiographically significant breach.

RESULTS Eighty-nine consecutive patients (690 screws) were included, of whom 46 (477 screws) were treated in the prone position and 43 (213 screws) in the lateral decubitus position. There were fewer breaches in the prone (n = 13, 2.7%) than the lateral decubitus (n = 15, 7.0%) group (p = 0.012). Nine (1.9%) radiographically significant breaches occurred in the prone group compared with 10 (4.7%) in the lateral decubitus group (p = 0.019), for a prone versus lateral decubitus PSP accuracy rate of 98.1% versus 95.3%. There were no significant differences in BMI between prone versus lateral decubitus cohorts (30.1 vs 29.6) or patients with screw breach versus those without (31.2 vs 29.5). In multivariate models, the prone position was the only significant protective factor for screw accuracy; no other significant risk factors for screw breach were identified.

CONCLUSIONS The present data suggest that pedicle screws placed with robotic assistance have higher placement accuracy in the prone position. Further studies will be needed to validate the accuracy of PSP in the lateral position as single-position surgery becomes more commonplace in the treatment of spinal disorders.

Lateral versus prone robot-assisted percutaneous pedicle screw placement: a CT-based comparative assessment of accuracy

J Neurosurg Spine 37:112–120, 2022

Single-position lateral lumbar interbody fusion (SP-LLIF) has recently gained significant popularity due to increased operative efficiency, but it remains technically challenging. Robot-assisted percutaneous pedicle screw (RAPPS) placement can facilitate screw placement in the lateral position. The authors have reported their initial experience with SP-LLIF with RA-PPS placement in the lateral position, and they have compared this accuracy with that of RA-PPS placement in the prone position.

METHODS The authors reviewed prospectively collected data from their first 100 lateral-position RA-PPSs. The authors graded screw accuracy on CT and compared it to the accuracy of all prone-position RA-PPS procedures during the same time period. The authors analyzed the effect of several demographic and perioperative metrics, as a whole and specifically for lateral-position RA-PPS placement.

RESULTS The authors placed 99 lateral-position RA-PPSs by using the ExcelsiusGPS robotic platform in the first 18 consecutive patients who underwent SP-LLIF with postoperative CT imaging; these patients were compared with 346 prone-position RA-PPSs that were placed in the first consecutive 64 patients during the same time period. All screws were placed at L1 to S1. Overall, the lateral group had 14 breaches (14.1%) and the prone group had 25 breaches (7.2%) (p = 0.032). The lateral group had 5 breaches (5.1%) greater than 2 mm (grade C or worse), and the prone group had 4 (1.2%) (p = 0.015). The operative level had an effect on the breach rate, with breach rates (grade C or worse) of 7.1% at L3 and 2.8% at L4. Most breaches were grade B (< 2 mm) and lateral, and no breach had clinical sequelae or required revision. Within the lateral group, multivariate regression analysis demonstrated that BMI and number of levels affected accuracy, but the side that was positioned up or down did not.

CONCLUSIONS RA-PPSs can improve the feasibility of SP-LLIF. Spine surgeons should be cautious and selective with this technique owing to decreased accuracy in the lateral position, particularly in obese patients. Further studies should compare SP-LLIF techniques performed while the patient is in the prone and lateral positions.

Robotic Stereotaxy in Cranial Neurosurgery

Neurosurgery 83:642–650, 2018

Modern-day stereotactic techniques have evolved to tackle the neurosurgical challenge of accurately and reproducibly accessing specific brain targets. Neurosurgical advances have beenmadein synergywith sophisticated technological developments and engineering innovations such as automated robotic platforms. Robotic systems offer a unique combination of dexterity, durability, indefatigability, and precision.

OBJECTIVE: To perform a systematic review of robotic integration for cranial stereotactic guidance in neurosurgery. Specifically, we comprehensively analyze the strengths and weaknesses of a spectrum of robotic technologies, past and present, including details pertaining to each system’s kinematic specifications and targeting accuracy profiles.

METHODS: Eligible articles on human clinical applications of cranial robotic-guided stereotactic systems between 1985 and 2017 were extracted from several electronic databases, with a focus on stereotactic biopsy procedures, stereoelectroencephalography, and deep brain stimulation electrode insertion.

RESULTS: Cranial robotic stereotactic systems feature serial or parallel architectures with 4 to 7 degrees of freedom, and frame-based or frameless registration. Indications for robotic assistance are diversifying, and include stereotactic biopsy, deep brain stimulation and stereoelectroencephalography electrode placement, ventriculostomy, and ablation procedures. Complication rates are low, and mainly consist of hemorrhage. Newer systems benefit fromincreasing targeting accuracy, intraoperative imaging ability, improved safety profiles, and reduced operating times.

CONCLUSION: We highlight emerging future directions pertaining to the integration of robotic technologies into future neurosurgical procedures. Notably, a trend toward miniaturization, cost-effectiveness, frameless registration, and increasing safety and accuracy characterize successful stereotactic robotic technologies.

State of Robotic Mastoidectomy: Literature Review

Over the past 30 years, the application of robotics in the field of neurotology has grown. Robots are able to perform increasingly complex tasks with ever improving accuracy, allowing them to be used in a broad array of applications. A mastoidectomy, in which a drill is used to remove a portion of the mastoid part of the temporal bone at the base of the skull, is one such application. To determine the current state of neurotologic robotics in the specific context of mastoidectomy, a review of the literature was carried out. This qualitative review explores what has been done in this field to date, as well as what has yet to be done. Although the research suggests that robotics can be and has been successfully used to assist with mastoidectomy, it also suggests the incompleteness of robotic development in the field.

At present, only 2 robotic systems have been approved by the U.S. Food and Drug Administration for neurosurgical use and the literature lacks evidence of meaningful clinical testing of new systems to change that. The cost of robotics also remains prohibitive. However, strides have been made, with at least 1 robot for mastoidectomy having reached the point of cadaveric trials. In addition, the research suggests some of the characteristics that should be considered when designing robots for mastoidectomy, such as burr size and the type of forces that should be applied.

Overall, the outlook for robots in neurotology, particularly mastoidectomy, is bright but some hurdles still remain to be overcome.

Navigation and Robotics in Spinal Surgery: Where Are We Now?

Neurosurgery 80:S86–S99, 2017

Spine surgery has experienced much technological innovation over the past several decades. The field has seen advancements in operative techniques, implants and biologics, and equipment such as computer-assisted navigation and surgical robotics.

With the arrival of real-time image guidance and navigation capabilities along with the computing ability to process and reconstruct these data into an interactive three-dimensional spinal “map”, so too have the applications of surgical robotic technology.

While spinal robotics and navigation represent promising potential for improving modern spinal surgery, it remains paramount to demonstrate its superiority as compared to traditional techniques prior to assimilation of its use amongst surgeons.

The applications for intraoperative navigation and image-guided robotics have expanded to surgical resection of spinal column and intradural tumors, revision procedures on arthrodesed spines, and deformity cases with distorted anatomy.

Additionally, these platforms may mitigate much of the harmful radiation exposure in minimally invasive surgery to which the patient, surgeon, and ancillary operating room staff are subjected. Spine surgery relies upon meticulous fine motor skills to manipulate neural elements and a steady hand while doing so, often exploiting small working corridors utilizing exposures that minimize collateral damage.

Additionally, the procedures may be long and arduous, predisposing the surgeon to both mental and physical fatigue. In light of these characteristics, spine surgery may actually be an ideal candidate for the integration of navigation and robotic-assisted procedures.

With this paper, we aim to critically evaluate the current literature and explore the options available for intraoperative navigation and robotic-assisted spine surgery.

Feasibility study for brain biopsies performed with the use of a head-mounted robot

Feasibility study for brain biopsies performed with the use of a head-mounted robotJ Neurosurg 123:737–742, 2015

Frame-based stereotactic interventions are considered the gold standard for brain biopsies, but they have limitations with regard to flexibility and patient comfort because of the bulky head ring attached to the patient. Frameless image guidance systems that use scalp fiducial markers offer more flexibility and patient comfort but provide less stability and accuracy during drilling and biopsy needle positioning. Head-mounted robot–guided biopsies could provide the advantages of these 2 techniques without the downsides. The goal of this study was to evaluate the feasibility and safety of a robotic guidance device, affixed to the patient’s skull through a small mounting platform, for use in brain biopsy procedures.

Methods This was a retrospective study of 37 consecutive patients who presented with supratentorial lesions and underwent brain biopsy procedures in which a surgical guidance robot was used to determine clinical outcomes and technical procedural operability.

Results The portable head-mounted device was well tolerated by the patients and enabled stable drilling and needle positioning during surgery. Flexible adjustments of predefined paths and selection of new trajectories were successfully performed intraoperatively without the need for manual settings and fixations. The patients experienced no permanent deficits or infections after surgery.

Conclusions The head-mounted robot–guided approach presented here combines the stability of a bone-mounted set-up with the flexibility and tolerability of frameless systems. By reducing human interference (i.e., manual parameter settings, calibrations, and adjustments), this technology might be particularly useful in neurosurgical interventions that necessitate multiple trajectories.

An Experimental Feasibility Study on Robotic Endonasal Telesurgery

Robotic teleneurosurgery

Neurosurgery 76:479–484, 2015

Novel robots have recently been developed specifically for endonasal surgery. They can deliver several thin, tentacle-like surgical instruments through a single nostril. Among the many potential advantages of such a robotic system is the prospect of telesurgery over long distances.

OBJECTIVE: To describe a phantom pituitary tumor removal done by a surgeon in Nashville, Tennessee, controlling a robot located approximately 800 km away in Chapel Hill, North Carolina, the first remote telesurgery experiment involving tentacle-like concentric tube manipulators.

METHODS: A phantom pituitary tumor removal experiment was conducted twice, once locally and once remotely, with the robotic system. Robot commands and video were transmitted across the Internet. The latency of the system was evaluated quantitatively in both local and remote cases to determine the effect of the 800-km distance between the surgeon and robot.

RESULTS: We measured a control and video latency of ,100 milliseconds in the remote case. Qualitatively, the surgeon was able to carry out the experiment easily and observed no discernable difference between the remote and local cases.

CONCLUSION: Telesurgery over long distances is feasible with this robotic system. In the longer term, this may enable expert skull base surgeons to help many more patients by performing surgeries remotely over long distances.

Current state-of-the-art and future perspectives of robotic technology in neurosurgery

Current state-of-the-art and future perspectives of robotic technology in neurosurgery-1

Neurosurg Rev (2014) 37:357–366

Neurosurgery is one of the most demanding surgical specialties in terms of precision requirements and surgical field limitations. Recent advancements in robotic technology have generated the possibility of incorporating advanced technological tools to the neurosurgical operating room.

Although previous studies have addressed the specific details of new robotic systems, there is very little literature on the strengths and drawbacks of past attempts, currently available platforms and prototypes in development. In this review, the authors present a critical historical analysis of the development of robotic technology in neurosurgery as well as a comprehensive summary of the currently available systems that can be expected to be incorporated to the neurosurgical armamentarium in the near future.

Finally, the authors present a critical analysis of the main technical challenges in robotic technology development at the present time (such as the design of improved systems for haptic feedback and the necessity of incorporating intraoperative imaging data) as well as the benefits which robotic technology is expected to bring to specific neurosurgical subspecialties in the near future.

Robot-Assisted Stereotactic Laser Ablation in Medically Intractable Epilepsy

Robot_Assisted_Stereotactic_Laser_Ablation_in

Operative Neurosurgery 10:167–173, 2014

Stereotactic laser ablation offers an advantage over open surgical procedures for treatment of epileptic foci, tumors, and other brain pathology. Robotassisted stereotactic laser ablation could offer an accurate, efficient, minimally invasive, and safe method for placement of an ablation catheter into the target.

OBJECTIVE: To determine the feasibility of placement of a stereotactic laser ablation catheter into a brain lesion with the use of robotic assistance, via a safe, accurate, efficient, and minimally invasive manner.

METHODS: A laser ablation catheter (Visualase, Inc) was placed by using robotic guidance (ROSA, Medtech Surgical, Inc) under general anesthesia into a localized epileptogenic periventricular heterotopic lesion in a 19-year-old woman with 10-year refractory focal seizure history. The laser applicator (1.65 mm diameter) position was confirmed by using magnetic resonance imaging (MRI). Ablation using the Visualase system was performed under multiplanar imaging with real-time thermal imaging and treatment estimates in each plane. A postablation MRI sequence (T1 postgadolinium contrast injection) was used to immediately confirm the ablation. RESULTS: MRI showed accurate skin entry point and trajectory, with the applicator advanced to the lesion’s distal boundary. Ablation was accomplished in less than 3 minutes of heating. The overall procedure, from time of skin incision to end of last ablation, was approximately 90 minutes. After confirmation of proper lesioning by using a T1 contrast-enhanced MRI, the applicator was removed, and the incision was closed using a single stitch. No hemorrhage or other untoward complication was visualized. The patient awoke without any complication, was observed overnight after admitting to a regular floor bed, and was discharged to home the following day.

CONCLUSION: This technique, using a combination of Visualase laser ablation, ROSA robot, and intraoperative MRI, facilitated a safe, efficacious, efficient, and minimally invasive approach that could be used for placement of 1 or multiple electrodes in the future.

Robotics and the spine: a review of current and ongoing applications

Virtual_Reality_and_Robotics_in

Neurosurg Focus 36 (3):E10, 2014

Robotics in the operating room has shown great use and versatility in multiple surgical fields. Robotassisted spine surgery has gained significant favor over its relatively short existence, due to its intuitive promise of higher surgical accuracy and better outcomes with fewer complications. Here, the authors analyze the existing literature on this growing technology in the era of minimally invasive spine surgery.

Methods. In an attempt to provide the most recent, up-to-date review of the current literature on robotic spine surgery, a search of the existing literature was conducted to obtain all relevant studies on robotics as it relates to its application in spine surgery and other interventions.

Results. In all, 45 articles were included in the analysis. The authors discuss the current status of this technology and its potential in multiple arenas of spinal interventions, mainly spine surgery and spine biomechanics testing.

Conclusions. There are numerous potential advantages and limitations to robotic spine surgery, as suggested in published case reports and in retrospective and prospective studies. Randomized controlled trials are few in number and show conflicting results regarding accuracy. The present limitations may be surmountable with future technological improvements, greater surgeon experience, reduced cost, improved operating room dynamics, and more training of surgical team members. Given the promise of robotics for improvements in spine surgery and spine biomechanics testing, more studies are needed to further explore the applicability of this technology in the spinal operating room. Due to the significant cost of the robotic equipment, studies are needed to substantiate that the increased equipment costs will result in significant benefits that will justify the expense.

Spinal Robotics: Current Applications and Future Perspectives

Robotics Spinal Surgery

Neurosurgery 72:A12–A18, 2013

Even though robotic technology holds great potential for performing spinal surgery and advancing neurosurgical techniques, it is of utmost importance to establish its practicality and to demonstrate better clinical outcomes compared with traditional techniques, especially in the current cost-effective era. Several systems have proved to be safe and reliable in the execution of tasks on a routine basis, are commercially available, and are used for specific indications in spine surgery. However, workflow, usability, interdisciplinary setups, efficacy, and cost-effectiveness have to be proven prospectively.

This article includes a short description of robotic structures and workflow, followed by preliminary results of a randomized prospective study comparing conventional free-hand techniques with routine spine navigation and robotic-assisted procedures. Additionally, we present cases performed with a spinal robotic device, assessing not only the accuracy of the robotic-assisted procedure but also other factors (eg, minimal invasiveness, radiation dosage, and learning curves).

Currently, the use of robotics in spinal surgery greatly enhances the application of minimally invasive procedures by increasing accuracy and reducing radiation exposure for patients and surgeons compared with standard procedures. Second-generation hardware and software upgrades of existing devices will enhance workflow and intraoperative setup. As more studies are published in this field, robot-assisted therapies will gain wider acceptance in the near future.

Frameless robotically targeted stereotactic brain biopsy

J Neurosurg 116:1002–1006, 2012. (http://thejns.org/doi/abs/10.3171/2012.1.JNS111746)

Frameless stereotactic brain biopsy has become an established procedure in many neurosurgical centers worldwide. Robotic modifications of image-guided frameless stereotaxy hold promise for making these procedures safer, more effective, and more efficient. The authors hypothesized that robotic brain biopsy is a safe, accurate procedure, with a high diagnostic yield and a safety profile comparable to other stereotactic biopsy methods.

Methods. This retrospective study included 41 patients undergoing frameless stereotactic brain biopsy of lesions (mean size 2.9 cm) for diagnostic purposes. All patients underwent image-guided, robotic biopsy in which the Surgi-Scope system was used in conjunction with scalp fiducial markers and a preoperatively selected target and trajectory. Forty-five procedures, with 50 supratentorial targets selected, were performed.

Results. The mean operative time was 44.6 minutes for the robotic biopsy procedures. This decreased over the second half of the study by 37%, from 54.7 to 34.5 minutes (p < 0.025). The diagnostic yield was 97.8% per procedure, with a second procedure being diagnostic in the single nondiagnostic case. Complications included one transient worsening of a preexisting deficit (2%) and another deficit that was permanent (2%). There were no infections.

Conclusions. Robotic biopsy involving a preselected target and trajectory is safe, accurate, efficient, and comparable to other procedures employing either frame-based stereotaxy or frameless, nonrobotic stereotaxy. It permits biopsy in all patients, including those with small target lesions. Robotic biopsy planning facilitates careful preoperative study and optimization of needle trajectory to avoid sulcal vessels, bridging veins, and ventricular penetration.