Contrast-Enhanced Ultrasound Perfusion Imaging of the Spinal Cord Before and After Surgical Decompression for Cervical Spondylotic Myelopathy

Neurosurgery 98:688–697, 2026

Contrast-enhanced ultrasound (CEUS) was applied intraoperatively to acquire spinal cord perfusion metrics before and after posterior decompression in 16 patients with cervical spondylotic myelopathy (CSM). The study details a reproducible surgical ultrasound window, CEUS acquisition parameters, time–intensity curve analysis, and statistical correlation of wash-in-time (WIT) with modified Japanese Orthopedic Association (mJOA) scores.

The technique proved feasible and safe, yielding pre- and postdecompression perfusion data without complications. Predecompression and postdecompression WIT correlated significantly with preoperative, 1-month, and 6-month mJOA scores, suggesting CEUS WIT may have prognostic utility for postoperative neurologic recovery.

Contrast-Enhanced Ultrasound (CEUS) Feasibility: CEUS can safely and effectively acquire spinal cord perfusion data both before and after surgical decompression in patients with cervical spondylotic myelopathy (CSM).

Wash-In Time (WIT) as Key Perfusion Parameter: WIT, defined as the time between initial appearance and peak concentration of contrast microbubbles, is the most relevant CEUS-derived perfusion metric and inversely correlates with neurologic status measured by modified Japanese Orthopedic Association (mJOA) scores.

Correlation with Neurologic Outcomes: Lower WIT values (indicating faster perfusion) are significantly associated with better preoperative and postoperative neurologic function at 1 and 6 months, suggesting potential as a prognostic biomarker.

No Significant Correlation with MRI Signal Change: Preoperative spinal cord signal changes on MRI, previously considered prognostic, did not correlate with WIT or other perfusion indices in this cohort.

Technical Approach: A small bony trough is created at the lateral lamina border to allow direct insonation of the compressed spinal cord, enabling both pre- and post-decompression CEUS imaging without interfering with standard surgical workflow.

No Major Complications: The technique was free of adverse events related to ultrasound contrast administration or the imaging process itself.

Small Sample and Pilot Nature: The study’s findings are limited by its small sample size (16 patients), and further multicenter, prospective studies are needed to validate CEUS as a predictive tool for surgical outcomes in CSM.

Clinical Implication: CEUS, and specifically preoperative WIT, shows promise for intraoperative prognostication and may help identify patients at risk for poor recovery or reperfusion injury after cervical decompression surgery.